mirror of
https://github.com/stargieg/bacnet-stack
synced 2025-10-26 23:35:52 +08:00
update to r3056 from https://sourceforge.net/p/bacnet/code/3056/tree/trunk/bacnet-stack/ add ipv6 and schedule support
This commit is contained in:
20
ports/xplained/readme.txt
Normal file
20
ports/xplained/readme.txt
Normal file
@@ -0,0 +1,20 @@
|
||||
BACnet MS/TP on Atmel XMEGA-A3BU XPLAINED evaluation board.
|
||||
|
||||
An RS-485 add-on board (daughterboard, shield) was designed
|
||||
to handle the RS-485 interface and some LEDs. See rs485-shield/
|
||||
folder for EAGLE CAD design files.
|
||||
|
||||
Use the Configuration "Debug-XPLAINED" and not in "Debug" or "Release".
|
||||
"CONF_BOARD_ENABLE_RS485_XPLAINED" is defined and used in led.c, rs485.c,
|
||||
and main.c for specific board I/O. When it is not defined, the I/O is
|
||||
either removed (i.e. led.c, main.c) or altered (rs485.c).
|
||||
|
||||
There are other defines in the "Debug-XPLAINED" Configuration
|
||||
which include other parts of the XPLAINED platform code.
|
||||
|
||||
For your own board, you could just change rs485.c, main.c, and led.c
|
||||
to use the I/O that you want to use, and not worry about the
|
||||
"CONF_BOARD_ENABLE_RS485_XPLAINED". Or you can leave the
|
||||
"CONF_BOARD_ENABLE_RS485_XPLAINED" in the files so that you can
|
||||
always test on the XPLAINED platform with Debug-XPLAINED, and use
|
||||
"Debug" or "Release" for your project.
|
||||
Reference in New Issue
Block a user