| * Copyright (C) 2006 Steve Karg <skarg@users.sourceforge.net>
 | |
| *
 | |
| * Permission is hereby granted, free of charge, to any person obtaining
 | |
| * a copy of this software and associated documentation files (the
 | |
| * "Software"), to deal in the Software without restriction, including
 | |
| * without limitation the rights to use, copy, modify, merge, publish,
 | |
| * distribute, sublicense, and/or sell copies of the Software, and to
 | |
| * permit persons to whom the Software is furnished to do so, subject to
 | |
| * the following conditions:
 | |
| *
 | |
| * The above copyright notice and this permission notice shall be included
 | |
| * in all copies or substantial portions of the Software.
 | |
| *
 | |
| * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
 | |
| * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
 | |
| * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT.
 | |
| * IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY
 | |
| * CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT,
 | |
| * TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE
 | |
| * SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
 | |
| *
 | |
| *********************************************************************/
 | |
| 
 | |
| /* Binary Value Objects - customize for your use */
 | |
| 
 | |
| #include <stdbool.h>
 | |
| #include <stdint.h>
 | |
| #include <stdio.h>
 | |
| #include "bacdef.h"
 | |
| #include "bacdcode.h"
 | |
| #include "bacenum.h"
 | |
| #include "config.h"     /* the custom stuff */
 | |
| #include "wp.h"
 | |
| #include "rp.h"
 | |
| #include "bv.h"
 | |
| 
 | |
| #define MAX_BINARY_VALUES 8
 | |
| 
 | |
| static BACNET_BINARY_PV Present_Value[MAX_BINARY_VALUES];
 | |
| 
 | |
| static void Binary_Value_Initialize(
 | |
|     void)
 | |
| {
 | |
|     static bool initialized = false;
 | |
|     unsigned i;
 | |
| 
 | |
|     if (!initialized) {
 | |
|         initialized = true;
 | |
|         for (i = 0; i < MAX_BINARY_VALUES; i++) {
 | |
|             Present_Value[i] = BINARY_INACTIVE;
 | |
|         }
 | |
|     }
 | |
| }
 | |
| 
 | |
| /* we simply have 0-n object instances. */
 | |
| bool Binary_Value_Valid_Instance(
 | |
|     uint32_t object_instance)
 | |
| {
 | |
|     if (object_instance < MAX_BINARY_VALUES)
 | |
|         return true;
 | |
| 
 | |
|     return false;
 | |
| }
 | |
| 
 | |
| /* we simply have 0-n object instances. */
 | |
| unsigned Binary_Value_Count(
 | |
|     void)
 | |
| {
 | |
|     return MAX_BINARY_VALUES;
 | |
| }
 | |
| 
 | |
| /* we simply have 0-n object instances. */
 | |
| uint32_t Binary_Value_Index_To_Instance(
 | |
|     unsigned index)
 | |
| {
 | |
|     return index;
 | |
| }
 | |
| 
 | |
| /* we simply have 0-n object instances.  */
 | |
| unsigned Binary_Value_Instance_To_Index(
 | |
|     uint32_t object_instance)
 | |
| {
 | |
|     unsigned index = MAX_BINARY_VALUES;
 | |
| 
 | |
|     if (object_instance < MAX_BINARY_VALUES)
 | |
|         index = object_instance;
 | |
| 
 | |
|     return index;
 | |
| }
 | |
| 
 | |
| BACNET_BINARY_PV Binary_Value_Present_Value(
 | |
|     uint32_t object_instance)
 | |
| {
 | |
|     BACNET_BINARY_PV value = BINARY_INACTIVE;
 | |
| 
 | |
|     Binary_Value_Initialize();
 | |
|     if (object_instance < MAX_BINARY_VALUES) {
 | |
|         value = Present_Value[object_instance];
 | |
|     }
 | |
| 
 | |
|     return value;
 | |
| }
 | |
| 
 | |
| /* note: the object name must be unique within this device */
 | |
| char *Binary_Value_Name(
 | |
|     uint32_t object_instance)
 | |
| {
 | |
|     static char text_string[16] = "";   /* okay for single thread */
 | |
| 
 | |
|     if (object_instance < MAX_BINARY_VALUES) {
 | |
|         sprintf(text_string, "BV-%lu", object_instance);
 | |
|         return text_string;
 | |
|     }
 | |
| 
 | |
|     return NULL;
 | |
| }
 | |
| 
 | |
| /* return apdu len, or -1 on error */
 | |
| int Binary_Value_Read_Property(
 | |
|     BACNET_READ_PROPERTY_DATA * rpdata)
 | |
| {
 | |
|     int len = 0;
 | |
|     int apdu_len = 0;   /* return value */
 | |
|     BACNET_BIT_STRING bit_string;
 | |
|     BACNET_CHARACTER_STRING char_string;
 | |
|     BACNET_BINARY_PV present_value = BINARY_INACTIVE;
 | |
|     BACNET_POLARITY polarity = POLARITY_NORMAL;
 | |
|     unsigned object_index = 0;
 | |
|     unsigned i = 0;
 | |
|     bool state = false;
 | |
|     uint8_t *apdu = NULL;
 | |
| 
 | |
|     Binary_Value_Initialize();
 | |
|     if ((rpdata == NULL) || (rpdata->application_data == NULL) ||
 | |
|         (rpdata->application_data_len == 0)) {
 | |
|         return 0;
 | |
|     }
 | |
|     apdu = rpdata->application_data;
 | |
|     switch (rpdata->object_property) {
 | |
|         case PROP_OBJECT_IDENTIFIER:
 | |
|             apdu_len =
 | |
|                 encode_application_object_id(&apdu[0], OBJECT_BINARY_VALUE,
 | |
|                 rpdata->object_instance);
 | |
|             break;
 | |
|             /* note: Name and Description don't have to be the same.
 | |
|                You could make Description writable and different */
 | |
|         case PROP_OBJECT_NAME:
 | |
|         case PROP_DESCRIPTION:
 | |
|             characterstring_init_ansi(&char_string,
 | |
|                 Binary_Value_Name(rpdata->object_instance));
 | |
|             apdu_len =
 | |
|                 encode_application_character_string(&apdu[0], &char_string);
 | |
|             break;
 | |
|         case PROP_OBJECT_TYPE:
 | |
|             apdu_len =
 | |
|                 encode_application_enumerated(&apdu[0], OBJECT_BINARY_VALUE);
 | |
|             break;
 | |
|         case PROP_PRESENT_VALUE:
 | |
|             present_value =
 | |
|                 Binary_Value_Present_Value(rpdata->object_instance);
 | |
|             apdu_len = encode_application_enumerated(&apdu[0], present_value);
 | |
|             break;
 | |
|         case PROP_STATUS_FLAGS:
 | |
|             /* note: see the details in the standard on how to use these */
 | |
|             bitstring_init(&bit_string);
 | |
|             bitstring_set_bit(&bit_string, STATUS_FLAG_IN_ALARM, false);
 | |
|             bitstring_set_bit(&bit_string, STATUS_FLAG_FAULT, false);
 | |
|             bitstring_set_bit(&bit_string, STATUS_FLAG_OVERRIDDEN, false);
 | |
|             bitstring_set_bit(&bit_string, STATUS_FLAG_OUT_OF_SERVICE, false);
 | |
|             apdu_len = encode_application_bitstring(&apdu[0], &bit_string);
 | |
|             break;
 | |
|         case PROP_EVENT_STATE:
 | |
|             /* note: see the details in the standard on how to use this */
 | |
|             apdu_len =
 | |
|                 encode_application_enumerated(&apdu[0], EVENT_STATE_NORMAL);
 | |
|             break;
 | |
|         case PROP_OUT_OF_SERVICE:
 | |
|             apdu_len = encode_application_boolean(&apdu[0], false);
 | |
|             break;
 | |
|         case PROP_POLARITY:
 | |
|             /* FIXME: figure out the polarity */
 | |
|             apdu_len = encode_application_enumerated(&apdu[0], polarity);
 | |
|             break;
 | |
|         default:
 | |
|             rpdata->error_class = ERROR_CLASS_PROPERTY;
 | |
|             rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
 | |
|             apdu_len = -1;
 | |
|             break;
 | |
|     }
 | |
|     /*  only array properties can have array options */
 | |
|     if ((apdu_len >= 0) && (rpdata->array_index != BACNET_ARRAY_ALL)) {
 | |
|         rpdata->error_class = ERROR_CLASS_PROPERTY;
 | |
|         rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
 | |
|         apdu_len = -1;
 | |
|     }
 | |
| 
 | |
|     return apdu_len;
 | |
| }
 | |
| 
 | |
| /* returns true if successful */
 | |
| bool Binary_Value_Write_Property(
 | |
|     BACNET_WRITE_PROPERTY_DATA * wp_data)
 | |
| {
 | |
|     bool status = false;        /* return value */
 | |
|     unsigned int object_index = 0;
 | |
|     unsigned int priority = 0;
 | |
|     BACNET_BINARY_PV level = BINARY_NULL;
 | |
|     int len = 0;
 | |
|     BACNET_APPLICATION_DATA_VALUE value;
 | |
| 
 | |
|     if (!Binary_Value_Valid_Instance(wp_data->object_instance)) {
 | |
|         wp_data->error_class = ERROR_CLASS_OBJECT;
 | |
|         wp_data->error_code = ERROR_CODE_UNKNOWN_OBJECT;
 | |
|         return false;
 | |
|     }
 | |
|     /* decode the some of the request */
 | |
|     len =
 | |
|         bacapp_decode_application_data(wp_data->application_data,
 | |
|         wp_data->application_data_len, &value);
 | |
|     /* FIXME: len < application_data_len: more data? */
 | |
|     if (len < 0) {
 | |
|         /* error while decoding - a value larger than we can handle */
 | |
|         wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|         wp_data->error_code = ERROR_CODE_VALUE_OUT_OF_RANGE;
 | |
|         return false;
 | |
|     }
 | |
|     if ((wp_data->object_property != PROP_PRIORITY_ARRAY) &&
 | |
|         (wp_data->array_index != BACNET_ARRAY_ALL)) {
 | |
|         /*  only array properties can have array options */
 | |
|         wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|         wp_data->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
 | |
|         return false;
 | |
|     }
 | |
|     switch (wp_data->object_property) {
 | |
|         case PROP_PRESENT_VALUE:
 | |
|             if (value.tag == BACNET_APPLICATION_TAG_ENUMERATED) {
 | |
|                 priority = wp_data->priority;
 | |
|                 /* Command priority 6 is reserved for use by Minimum On/Off
 | |
|                    algorithm and may not be used for other purposes in any
 | |
|                    object. */
 | |
|                 if (priority && (priority <= BACNET_MAX_PRIORITY) &&
 | |
|                     (priority != 6 /* reserved */ ) &&
 | |
|                     (value.type.Enumerated >= MIN_BINARY_PV) &&
 | |
|                     (value.type.Enumerated <= MAX_BINARY_PV)) {
 | |
|                     level = value.type.Enumerated;
 | |
|                     object_index =
 | |
|                         Binary_Value_Instance_To_Index
 | |
|                         (wp_data->object_instance);
 | |
|                     priority--;
 | |
|                     /* NOTE: this Binary value has no priority array */
 | |
|                     Present_Value[object_index] = level;
 | |
|                     /* Note: you could set the physical output here if we
 | |
|                        are the highest priority.
 | |
|                        However, if Out of Service is TRUE, then don't set the
 | |
|                        physical output. */
 | |
|                     status = true;
 | |
|                 } else if (priority == 6) {
 | |
|                     /* Command priority 6 is reserved for use by Minimum On/Off
 | |
|                        algorithm and may not be used for other purposes in any
 | |
|                        object. */
 | |
|                     wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|                     wp_data->error_code = ERROR_CODE_WRITE_ACCESS_DENIED;
 | |
|                 } else {
 | |
|                     wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|                     wp_data->error_code = ERROR_CODE_VALUE_OUT_OF_RANGE;
 | |
|                 }
 | |
|             } else if (value.tag == BACNET_APPLICATION_TAG_NULL) {
 | |
| #if 0
 | |
|                 /* NOTE: this Binary Value has no priority array */
 | |
|                 level = BINARY_NULL;
 | |
|                 object_index =
 | |
|                     Binary_Value_Instance_To_Index(wp_data->object_instance);
 | |
|                 priority = wp_data->priority;
 | |
|                 if (priority && (priority <= BACNET_MAX_PRIORITY)) {
 | |
|                     priority--;
 | |
|                     Binary_Value_Level[object_index][priority] = level;
 | |
|                     /* Note: you could set the physical output here to the next
 | |
|                        highest priority, or to the relinquish default if no
 | |
|                        priorities are set.
 | |
|                        However, if Out of Service is TRUE, then don't set the
 | |
|                        physical output.  This comment may apply to the
 | |
|                        main loop (i.e. check out of service before changing output) */
 | |
|                     status = true;
 | |
|                 } else {
 | |
|                     wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|                     wp_data->error_code = ERROR_CODE_VALUE_OUT_OF_RANGE;
 | |
|                 }
 | |
| #else
 | |
|                 wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|                 wp_data->error_code = ERROR_CODE_INVALID_DATA_TYPE;
 | |
| #endif
 | |
|             } else {
 | |
|                 wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|                 wp_data->error_code = ERROR_CODE_INVALID_DATA_TYPE;
 | |
|             }
 | |
|             break;
 | |
|         case PROP_OUT_OF_SERVICE:
 | |
| #if 0
 | |
|             if (value.tag == BACNET_APPLICATION_TAG_BOOLEAN) {
 | |
|                 object_index =
 | |
|                     Binary_Value_Instance_To_Index(wp_data->object_instance);
 | |
|                 Binary_Value_Out_Of_Service[object_index] = value.type.Boolean;
 | |
|                 status = true;
 | |
|             } else {
 | |
|                 wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|                 wp_data->error_code = ERROR_CODE_INVALID_DATA_TYPE;
 | |
|             }
 | |
|             break;
 | |
| #endif
 | |
|         case PROP_OBJECT_IDENTIFIER:
 | |
|         case PROP_OBJECT_NAME:
 | |
|         case PROP_OBJECT_TYPE:
 | |
|         case PROP_STATUS_FLAGS:
 | |
|         case PROP_EVENT_STATE:
 | |
|         case PROP_POLARITY:
 | |
|             wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|             wp_data->error_code = ERROR_CODE_WRITE_ACCESS_DENIED;
 | |
|             break;
 | |
|         default:
 | |
|             wp_data->error_class = ERROR_CLASS_PROPERTY;
 | |
|             wp_data->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
 | |
|             break;
 | |
|     }
 | |
| 
 | |
|     return status;
 | |
| }
 | 