				|  | @ -1,6 +1,6 @@ | |||
| .TH "mbusd" 8 "13 September 2003" "mbusd @VERSION@"  | ||||
| .TH "mbusd" 8 "26 October 2003" "mbusd @VERSION@"  | ||||
| .SH NAME | ||||
| mbusd \- OpenMODBUS/TCP to MODBUS RTU gateway server | ||||
| mbusd \- MODBUS/TCP to MODBUS/RTU gateway server | ||||
| .SH SYNOPSIS | ||||
| .B mbusd | ||||
| .RB [ -h ] | ||||
|  | @ -26,7 +26,7 @@ mbusd \- OpenMODBUS/TCP to MODBUS RTU gateway server | |||
| .RB [ -T | ||||
| .IR value ]  | ||||
| .SH DESCRIPTION | ||||
| \fImbusd\fR is OpenMODBUS/TCP to MODBUS RTU gateway server. | ||||
| \fImbusd\fR is MODBUS/TCP to MODBUS/RTU gateway server (currently master mode only is supported). | ||||
| .SH OPTIONS | ||||
| .IP \fB-h\fR | ||||
| Usage help. | ||||
|  | @ -39,7 +39,7 @@ If \fImbusd\fR was compiled in debug mode, valid log levels is up to 9, | |||
| where log levels above 2 forces logging of information about additional  | ||||
| internal events. | ||||
| .IP "\fB-L \fIname\fR" | ||||
| Specifies log file name. | ||||
| Specifies log file name. Value '-' forces log data output to STDOUT only if \fB-d\fR switch was given. | ||||
| .IP "\fB-p \fIname\fR" | ||||
| Specifies serial port device name. | ||||
| .IP "\fB-s \fIvalue\fR" | ||||
|  | @ -60,9 +60,9 @@ Specifies connection timeout value in seconds. 0 - no timeout. | |||
| Because MODBUS RTU protocol have situations which can't straightforwardly  | ||||
| translated into MODBUS/TCP protocol entities, \fImbusd\fR extends standard excepton codes set. | ||||
| In case of situation when \fImbusd\fR received response with invalid CRC and can't correct | ||||
| error by re-request, it returns MODBUS/TCP packet with exception code 128. In case of situation  | ||||
| error by re-request, it return MODBUS/TCP packet with exception code 128. In case of situation  | ||||
| when \fImbusd\fR can't receive response from MODBUS RTU device (e.g. addressed controller  | ||||
| is not present on the network), it returns MODBUS/TCP packet with exception code 129. | ||||
| is not present on the network), it return MODBUS/TCP packet with exception code 129. | ||||
| .SH FILES | ||||
| .PP | ||||
| The default location of the \fImbusd\fR log file is: | ||||
|  |  | |||