mirror of
https://github.com/thingsboard/thingsboard-gateway
synced 2025-10-26 22:31:42 +08:00
Merge branch 'master' of https://github.com/thingsboard/thingsboard-gateway into feature/grpc-api
This commit is contained in:
2
setup.py
2
setup.py
@@ -47,7 +47,7 @@ setup(
|
||||
'thingsboard_gateway.extensions.mqtt', 'thingsboard_gateway.extensions.modbus', 'thingsboard_gateway.extensions.opcua',
|
||||
'thingsboard_gateway.extensions.ble', 'thingsboard_gateway.extensions.serial', 'thingsboard_gateway.extensions.request',
|
||||
'thingsboard_gateway.extensions.can', 'thingsboard_gateway.extensions.bacnet', 'thingsboard_gateway.extensions.odbc',
|
||||
'thingsboard_gateway.extensions.rest', 'thingsboard_gateway.extensions.snmp', 'thingsboard_gateway.extensions.ftp'
|
||||
'thingsboard_gateway.extensions.rest', 'thingsboard_gateway.extensions.snmp', 'thingsboard_gateway.extensions.ftp',
|
||||
],
|
||||
install_requires=[
|
||||
'jsonpath-rw',
|
||||
|
||||
@@ -1,16 +1,17 @@
|
||||
{
|
||||
"server": {
|
||||
"type": "tcp",
|
||||
"master": {
|
||||
"slaves": [
|
||||
{
|
||||
"host": "127.0.0.1",
|
||||
"port": 5020,
|
||||
"timeout": 35,
|
||||
"port": 5021,
|
||||
"type": "tcp",
|
||||
"method": "socket",
|
||||
"timeout": 35,
|
||||
"byteOrder": "BIG",
|
||||
"retries": true,
|
||||
"retryOnEmpty": true,
|
||||
"retryOnInvalid": true,
|
||||
"devices": [
|
||||
{
|
||||
"pollPeriod": 5000,
|
||||
"unitId": 1,
|
||||
"deviceName": "Temp Sensor",
|
||||
"attributesPollPeriod": 5000,
|
||||
@@ -171,5 +172,77 @@
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"slave": {
|
||||
"type": "tcp",
|
||||
"host": "127.0.0.1",
|
||||
"port": 5026,
|
||||
"method": "socket",
|
||||
"deviceName": "Gateway",
|
||||
"deviceType": "default",
|
||||
"pollPeriod": 5000,
|
||||
"sendDataToThingsBoard": false,
|
||||
"byteOrder": "BIG",
|
||||
"unitId": 0,
|
||||
"values": {
|
||||
"holding_registers": [
|
||||
{
|
||||
"attributes": [
|
||||
{
|
||||
"address": 1,
|
||||
"type": "string",
|
||||
"tag": "sm",
|
||||
"objectsCount": 1,
|
||||
"value": "ON"
|
||||
}
|
||||
],
|
||||
"timeseries": [
|
||||
{
|
||||
"address": 2,
|
||||
"type": "int",
|
||||
"tag": "smm",
|
||||
"objectsCount": 1,
|
||||
"value": "12334"
|
||||
}
|
||||
],
|
||||
"attributeUpdates": [
|
||||
{
|
||||
"tag": "shared_attribute_write",
|
||||
"type": "32int",
|
||||
"functionCode": 6,
|
||||
"objectsCount": 2,
|
||||
"address": 29,
|
||||
"value": 1243
|
||||
}
|
||||
],
|
||||
"rpc": [
|
||||
{
|
||||
"tag": "setValue",
|
||||
"type": "bits",
|
||||
"functionCode": 5,
|
||||
"objectsCount": 1,
|
||||
"address": 31,
|
||||
"value": 22
|
||||
}
|
||||
]
|
||||
}
|
||||
],
|
||||
"coils_initializer": [
|
||||
{
|
||||
"attributes": [
|
||||
{
|
||||
"address": 5,
|
||||
"type": "string",
|
||||
"tag": "sm",
|
||||
"objectsCount": 1,
|
||||
"value": "12"
|
||||
}
|
||||
],
|
||||
"timeseries": [],
|
||||
"attributeUpdates": [],
|
||||
"rpc": []
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -47,6 +47,7 @@ connectors:
|
||||
# type: modbus
|
||||
# configuration: modbus_serial.json
|
||||
#
|
||||
#
|
||||
# -
|
||||
# name: OPC-UA Connector
|
||||
# type: opcua
|
||||
|
||||
@@ -0,0 +1,54 @@
|
||||
# Copyright 2021. ThingsBoard
|
||||
#
|
||||
# Licensed under the Apache License, Version 2.0 (the "License");
|
||||
# you may not use this file except in compliance with the License.
|
||||
# You may obtain a copy of the License at
|
||||
#
|
||||
# http://www.apache.org/licenses/LICENSE-2.0
|
||||
#
|
||||
# Unless required by applicable law or agreed to in writing, software
|
||||
# distributed under the License is distributed on an "AS IS" BASIS,
|
||||
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
||||
# See the License for the specific language governing permissions and
|
||||
# limitations under the License.
|
||||
|
||||
from simplejson import dumps
|
||||
|
||||
from thingsboard_gateway.connectors.connector import log
|
||||
|
||||
|
||||
class BackwardCompatibilityAdapter:
|
||||
def __init__(self, config):
|
||||
self.__config = config
|
||||
self.__keys = ['host', 'port', 'type', 'method', 'timeout', 'byteOrder', 'wordOrder', 'retries', 'retryOnEmpty',
|
||||
'retryOnInvalid', 'baudrate']
|
||||
|
||||
@staticmethod
|
||||
def __save_json_config_file(config):
|
||||
with open('config/modbus_new.json', 'w') as file:
|
||||
file.writelines(dumps(config, sort_keys=False, indent=' ', separators=(',', ': ')))
|
||||
|
||||
def convert(self):
|
||||
if not self.__config.get('server'):
|
||||
return self.__config
|
||||
|
||||
log.warning(
|
||||
'You are using old configuration structure for Modbus connector. It will be DEPRECATED in the future '
|
||||
'version! New config file "modbus_new.json" was generated in config/ folder. Please, use it.')
|
||||
|
||||
slaves = []
|
||||
for device in self.__config['server'].get('devices', []):
|
||||
slave = {**device}
|
||||
|
||||
for key in self.__keys:
|
||||
if not device.get(key):
|
||||
slave[key] = self.__config['server'].get(key)
|
||||
|
||||
slave['pollPeriod'] = slave['timeseriesPollPeriod']
|
||||
|
||||
slaves.append(slave)
|
||||
|
||||
result_dict = {'master': {'slaves': slaves}, 'slave': self.__config.get('slave')}
|
||||
self.__save_json_config_file(result_dict)
|
||||
|
||||
return result_dict
|
||||
@@ -12,13 +12,12 @@
|
||||
# See the License for the specific language governing permissions and
|
||||
# limitations under the License.
|
||||
|
||||
import threading
|
||||
import time
|
||||
from threading import Thread
|
||||
from time import sleep, time
|
||||
from queue import Queue
|
||||
from random import choice
|
||||
from string import ascii_lowercase
|
||||
|
||||
from thingsboard_gateway.tb_utility.tb_loader import TBModuleLoader
|
||||
from thingsboard_gateway.tb_utility.tb_utility import TBUtility
|
||||
|
||||
# Try import Pymodbus library or install it and import
|
||||
@@ -30,23 +29,56 @@ except ImportError:
|
||||
TBUtility.install_package('pyserial')
|
||||
from pymodbus.constants import Defaults
|
||||
|
||||
from pymodbus.client.sync import ModbusTcpClient, ModbusUdpClient, ModbusSerialClient, ModbusRtuFramer, \
|
||||
ModbusSocketFramer
|
||||
from pymodbus.bit_write_message import WriteSingleCoilResponse, WriteMultipleCoilsResponse
|
||||
from pymodbus.register_write_message import WriteMultipleRegistersResponse, WriteSingleRegisterResponse
|
||||
from pymodbus.register_read_message import ReadRegistersResponseBase
|
||||
from pymodbus.bit_read_message import ReadBitsResponseBase
|
||||
from pymodbus.client.sync import ModbusTcpClient, ModbusUdpClient, ModbusSerialClient
|
||||
from pymodbus.client.sync import ModbusRtuFramer, ModbusSocketFramer, ModbusAsciiFramer
|
||||
from pymodbus.exceptions import ConnectionException
|
||||
from pymodbus.server.asynchronous import StartTcpServer, StartUdpServer, StartSerialServer, StopServer
|
||||
from pymodbus.device import ModbusDeviceIdentification
|
||||
from pymodbus.version import version
|
||||
from pymodbus.datastore import ModbusSlaveContext, ModbusServerContext
|
||||
from pymodbus.datastore import ModbusSparseDataBlock
|
||||
|
||||
from thingsboard_gateway.connectors.connector import Connector, log
|
||||
from thingsboard_gateway.connectors.modbus.constants import *
|
||||
from thingsboard_gateway.connectors.modbus.bytes_modbus_uplink_converter import BytesModbusUplinkConverter
|
||||
from thingsboard_gateway.connectors.modbus.slave import Slave
|
||||
from thingsboard_gateway.connectors.modbus.backward_compability_adapter import BackwardCompatibilityAdapter
|
||||
from thingsboard_gateway.connectors.modbus.bytes_modbus_downlink_converter import BytesModbusDownlinkConverter
|
||||
|
||||
CONVERTED_DATA_SECTIONS = [ATTRIBUTES_PARAMETER, TELEMETRY_PARAMETER]
|
||||
FRAMER_TYPE = {
|
||||
'rtu': ModbusRtuFramer,
|
||||
'socket': ModbusSocketFramer,
|
||||
'ascii': ModbusAsciiFramer
|
||||
}
|
||||
SLAVE_TYPE = {
|
||||
'tcp': StartTcpServer,
|
||||
'udp': StartUdpServer,
|
||||
'serial': StartSerialServer
|
||||
}
|
||||
FUNCTION_TYPE = {
|
||||
'coils_initializer': 'ci',
|
||||
'holding_registers': 'hr',
|
||||
'input_registers': 'ir',
|
||||
'discrete_inputs': 'di'
|
||||
}
|
||||
FUNCTION_CODE_WRITE = {
|
||||
'holding_registers': (6, 16),
|
||||
'coils_initializer': (5, 15)
|
||||
}
|
||||
FUNCTION_CODE_READ = {
|
||||
'holding_registers': 3,
|
||||
'coils_initializer': 1,
|
||||
'input_registers': 4,
|
||||
'discrete_inputs': 2
|
||||
}
|
||||
|
||||
|
||||
class ModbusConnector(Connector, threading.Thread):
|
||||
class ModbusConnector(Connector, Thread):
|
||||
process_requests = Queue(-1)
|
||||
|
||||
def __init__(self, gateway, config, connector_type):
|
||||
self.statistics = {STATISTIC_MESSAGE_RECEIVED_PARAMETER: 0,
|
||||
@@ -54,28 +86,25 @@ class ModbusConnector(Connector, threading.Thread):
|
||||
super().__init__()
|
||||
self.__gateway = gateway
|
||||
self._connector_type = connector_type
|
||||
self.__config = config.get(CONFIG_SERVER_SECTION_PARAMETER)
|
||||
self.__previous_master_config = dict()
|
||||
self.__current_master, self.__available_functions = self.__configure_master()
|
||||
self.__default_config_parameters = [HOST_PARAMETER,
|
||||
PORT_PARAMETER,
|
||||
BAUDRATE_PARAMETER,
|
||||
TIMEOUT_PARAMETER,
|
||||
METHOD_PARAMETER,
|
||||
STOPBITS_PARAMETER,
|
||||
BYTESIZE_PARAMETER,
|
||||
PARITY_PARAMETER,
|
||||
STRICT_PARAMETER,
|
||||
TYPE_PARAMETER]
|
||||
self.__byte_order = self.__config.get(BYTE_ORDER_PARAMETER)
|
||||
self.__word_order = self.__config.get(WORD_ORDER_PARAMETER)
|
||||
self.__devices = {}
|
||||
|
||||
self.__backward_compatibility_adapter = BackwardCompatibilityAdapter(config)
|
||||
self.__config = self.__backward_compatibility_adapter.convert()
|
||||
|
||||
self.setName(self.__config.get("name", 'Modbus Default ' + ''.join(choice(ascii_lowercase) for _ in range(5))))
|
||||
self.__load_converters()
|
||||
self.__connected = False
|
||||
self.__stopped = False
|
||||
self.daemon = True
|
||||
self.__data_to_convert_queue = Queue()
|
||||
|
||||
if self.__config.get('slave'):
|
||||
self.__slave_thread = Thread(target=self.__configure_and_run_slave, args=(self.__config['slave'],),
|
||||
daemon=True, name='Gateway as a slave')
|
||||
self.__slave_thread.start()
|
||||
|
||||
if config['slave'].get('sendDataToThingsBoard', False):
|
||||
self.__modify_main_config()
|
||||
|
||||
self.__slaves = []
|
||||
self.__load_slaves()
|
||||
|
||||
def is_connected(self):
|
||||
return self.__connected
|
||||
@@ -83,29 +112,93 @@ class ModbusConnector(Connector, threading.Thread):
|
||||
def open(self):
|
||||
self.__stopped = False
|
||||
self.start()
|
||||
log.info("Starting Modbus connector")
|
||||
|
||||
def run(self):
|
||||
self.__connected = True
|
||||
|
||||
while True:
|
||||
time.sleep(.2)
|
||||
self.__process_devices()
|
||||
|
||||
if not self.__data_to_convert_queue.empty():
|
||||
for _ in range(self.__data_to_convert_queue.qsize()):
|
||||
thread = threading.Thread(target=self.__convert_and_save_data, args=(self.__data_to_convert_queue,),
|
||||
daemon=True)
|
||||
if not self.__stopped and not ModbusConnector.process_requests.empty():
|
||||
thread = Thread(target=self.__process_slaves, daemon=True)
|
||||
thread.start()
|
||||
|
||||
if self.__stopped:
|
||||
break
|
||||
|
||||
def __convert_and_save_data(self, queue):
|
||||
device, current_device_config, config, device_responses = queue.get()
|
||||
sleep(.2)
|
||||
|
||||
@staticmethod
|
||||
def __configure_and_run_slave(config):
|
||||
identity = None
|
||||
if config.get('identity'):
|
||||
identity = ModbusDeviceIdentification()
|
||||
identity.VendorName = config['identity'].get('vendorName', '')
|
||||
identity.ProductCode = config['identity'].get('productCode', '')
|
||||
identity.VendorUrl = config['identity'].get('vendorUrl', '')
|
||||
identity.ProductName = config['identity'].get('productName', '')
|
||||
identity.ModelName = config['identity'].get('ModelName', '')
|
||||
identity.MajorMinorRevision = version.short()
|
||||
|
||||
blocks = {}
|
||||
for (key, value) in config.get('values').items():
|
||||
values = {}
|
||||
converter = BytesModbusDownlinkConverter({})
|
||||
for item in value:
|
||||
for section in ('attributes', 'timeseries', 'attributeUpdates', 'rpc'):
|
||||
for val in item[section]:
|
||||
function_code = FUNCTION_CODE_WRITE[key][0] if val['objectsCount'] <= 1 else \
|
||||
FUNCTION_CODE_WRITE[key][1]
|
||||
converted_value = converter.convert(
|
||||
{**val,
|
||||
'device': config.get('deviceName', 'Gateway'), 'functionCode': function_code,
|
||||
'byteOrder': config['byteOrder']},
|
||||
{'data': {'params': val['value']}})
|
||||
values[val['address']] = converted_value
|
||||
|
||||
blocks[FUNCTION_TYPE[key]] = ModbusSparseDataBlock(values)
|
||||
|
||||
context = ModbusServerContext(slaves=ModbusSlaveContext(**blocks), single=True)
|
||||
SLAVE_TYPE[config['type']](context, identity=identity,
|
||||
address=(config.get('host'), config.get('port')) if (
|
||||
config['type'] == 'tcp' or 'udp') else None,
|
||||
port=config.get('port') if config['type'] == 'serial' else None,
|
||||
framer=FRAMER_TYPE[config['method']])
|
||||
|
||||
def __modify_main_config(self):
|
||||
config = self.__config['slave']
|
||||
|
||||
values = config.pop('values')
|
||||
device = config
|
||||
|
||||
for (register, reg_values) in values.items():
|
||||
for value in reg_values:
|
||||
for section in ('attributes', 'timeseries', 'attributeUpdates', 'rpc'):
|
||||
if not device.get(section):
|
||||
device[section] = []
|
||||
|
||||
for item in value.get(section, []):
|
||||
device[section].append({**item, 'functionCode': FUNCTION_CODE_READ[register]})
|
||||
|
||||
self.__config['master']['slaves'].append(device)
|
||||
|
||||
def __load_slaves(self):
|
||||
self.__slaves = [
|
||||
Slave(**{**device, 'connector': self, 'gateway': self.__gateway, 'callback': ModbusConnector.callback}) for
|
||||
device in self.__config.get('master', {'slaves': []}).get('slaves', [])]
|
||||
|
||||
@classmethod
|
||||
def callback(cls, slave):
|
||||
cls.process_requests.put(slave)
|
||||
|
||||
@property
|
||||
def connector_type(self):
|
||||
return self._connector_type
|
||||
|
||||
def __convert_and_save_data(self, config_tuple):
|
||||
device, current_device_config, config, device_responses = config_tuple
|
||||
converted_data = {}
|
||||
|
||||
try:
|
||||
converted_data = self.__devices[device][UPLINK_PREFIX + CONVERTER_PARAMETER].convert(
|
||||
converted_data = device.config[UPLINK_PREFIX + CONVERTER_PARAMETER].convert(
|
||||
config=config,
|
||||
data=device_responses)
|
||||
except Exception as e:
|
||||
@@ -117,20 +210,22 @@ class ModbusConnector(Connector, threading.Thread):
|
||||
ATTRIBUTES_PARAMETER: []
|
||||
}
|
||||
|
||||
if current_device_config.get(SEND_DATA_ONLY_ON_CHANGE_PARAMETER):
|
||||
if current_device_config.get('sendDataOnlyOnChange'):
|
||||
self.statistics[STATISTIC_MESSAGE_RECEIVED_PARAMETER] += 1
|
||||
|
||||
for converted_data_section in CONVERTED_DATA_SECTIONS:
|
||||
for current_section_dict in converted_data[converted_data_section]:
|
||||
for key, value in current_section_dict.items():
|
||||
if self.__devices[device][LAST_PREFIX + converted_data_section].get(key) is None or \
|
||||
self.__devices[device][LAST_PREFIX + converted_data_section][key] != value:
|
||||
self.__devices[device][LAST_PREFIX + converted_data_section][key] = value
|
||||
if device.config[LAST_PREFIX + converted_data_section].get(key) is None or \
|
||||
device.config[LAST_PREFIX + converted_data_section][key] != value:
|
||||
device.config[LAST_PREFIX + converted_data_section][key] = value
|
||||
to_send[converted_data_section].append({key: value})
|
||||
elif converted_data and current_device_config.get(SEND_DATA_ONLY_ON_CHANGE_PARAMETER) is None or \
|
||||
not current_device_config.get(SEND_DATA_ONLY_ON_CHANGE_PARAMETER):
|
||||
elif converted_data and current_device_config.get('sendDataOnlyOnChange') is None or \
|
||||
not current_device_config.get('sendDataOnlyOnChange'):
|
||||
self.statistics[STATISTIC_MESSAGE_RECEIVED_PARAMETER] += 1
|
||||
|
||||
for converted_data_section in CONVERTED_DATA_SECTIONS:
|
||||
self.__devices[device][LAST_PREFIX + converted_data_section] = converted_data[
|
||||
device.config[LAST_PREFIX + converted_data_section] = converted_data[
|
||||
converted_data_section]
|
||||
to_send[converted_data_section] = converted_data[converted_data_section]
|
||||
|
||||
@@ -138,225 +233,142 @@ class ModbusConnector(Connector, threading.Thread):
|
||||
self.__gateway.send_to_storage(self.get_name(), to_send)
|
||||
self.statistics[STATISTIC_MESSAGE_SENT_PARAMETER] += 1
|
||||
|
||||
def __load_converters(self):
|
||||
try:
|
||||
for device in self.__config[CONFIG_DEVICES_SECTION_PARAMETER]:
|
||||
if self.__config.get(UPLINK_PREFIX + CONVERTER_PARAMETER) is not None:
|
||||
converter = TBModuleLoader.import_module(self._connector_type,
|
||||
self.__config[UPLINK_PREFIX + CONVERTER_PARAMETER])(device)
|
||||
else:
|
||||
converter = BytesModbusUplinkConverter(device)
|
||||
if self.__config.get(DOWNLINK_PREFIX + CONVERTER_PARAMETER) is not None:
|
||||
downlink_converter = TBModuleLoader.import_module(self._connector_type, self.__config[
|
||||
DOWNLINK_PREFIX + CONVERTER_PARAMETER])(device)
|
||||
else:
|
||||
downlink_converter = BytesModbusDownlinkConverter(device)
|
||||
if device.get(DEVICE_NAME_PARAMETER) not in self.__gateway.get_devices():
|
||||
self.__gateway.add_device(device.get(DEVICE_NAME_PARAMETER), {CONNECTOR_PARAMETER: self},
|
||||
device_type=device.get(DEVICE_TYPE_PARAMETER))
|
||||
self.__devices[device[DEVICE_NAME_PARAMETER]] = {CONFIG_SECTION_PARAMETER: device,
|
||||
UPLINK_PREFIX + CONVERTER_PARAMETER: converter,
|
||||
DOWNLINK_PREFIX + CONVERTER_PARAMETER: downlink_converter,
|
||||
NEXT_PREFIX + ATTRIBUTES_PARAMETER + CHECK_POSTFIX: 0,
|
||||
NEXT_PREFIX + TIMESERIES_PARAMETER + CHECK_POSTFIX: 0,
|
||||
TELEMETRY_PARAMETER: {},
|
||||
ATTRIBUTES_PARAMETER: {},
|
||||
LAST_PREFIX + TELEMETRY_PARAMETER: {},
|
||||
LAST_PREFIX + ATTRIBUTES_PARAMETER: {},
|
||||
CONNECTION_ATTEMPT_PARAMETER: 0
|
||||
}
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
|
||||
def close(self):
|
||||
self.__stopped = True
|
||||
self.__stop_connections_to_masters()
|
||||
StopServer()
|
||||
log.info('%s has been stopped.', self.get_name())
|
||||
|
||||
def get_name(self):
|
||||
return self.name
|
||||
|
||||
def __process_devices(self):
|
||||
for device in self.__devices:
|
||||
current_time = time.time()
|
||||
device_responses = {TIMESERIES_PARAMETER: {},
|
||||
ATTRIBUTES_PARAMETER: {},
|
||||
}
|
||||
def __process_slaves(self):
|
||||
# TODO: write documentation
|
||||
device = ModbusConnector.process_requests.get()
|
||||
|
||||
device_responses = {'timeseries': {}, 'attributes': {}}
|
||||
current_device_config = {}
|
||||
try:
|
||||
for config_section in device_responses:
|
||||
if self.__devices[device][CONFIG_SECTION_PARAMETER].get(config_section) is not None:
|
||||
current_device_config = self.__devices[device][CONFIG_SECTION_PARAMETER]
|
||||
unit_id = current_device_config[UNIT_ID_PARAMETER]
|
||||
if self.__devices[device][NEXT_PREFIX + config_section + CHECK_POSTFIX] < current_time:
|
||||
if device.config.get(config_section) is not None:
|
||||
current_device_config = device.config
|
||||
|
||||
self.__connect_to_current_master(device)
|
||||
if not self.__current_master.is_socket_open() or not len(
|
||||
|
||||
if not device.config['master'].is_socket_open() or not len(
|
||||
current_device_config[config_section]):
|
||||
continue
|
||||
|
||||
# Reading data from device
|
||||
for interested_data in range(len(current_device_config[config_section])):
|
||||
current_data = current_device_config[config_section][interested_data]
|
||||
current_data[DEVICE_NAME_PARAMETER] = device
|
||||
input_data = self.__function_to_device(current_data, unit_id)
|
||||
input_data = self.__function_to_device(device, current_data)
|
||||
device_responses[config_section][current_data[TAG_PARAMETER]] = {
|
||||
"data_sent": current_data,
|
||||
"input_data": input_data}
|
||||
|
||||
log.debug("Checking %s for device %s", config_section, device)
|
||||
self.__devices[device][NEXT_PREFIX + config_section + CHECK_POSTFIX] = current_time + \
|
||||
current_device_config[
|
||||
config_section + POLL_PERIOD_POSTFIX] / 1000
|
||||
log.debug('Device response: ', device_responses)
|
||||
|
||||
if device_responses.get('timeseries') or device_responses.get('attributes'):
|
||||
self.__data_to_convert_queue.put((device, current_device_config, {
|
||||
self.__convert_and_save_data((device, current_device_config, {
|
||||
**current_device_config,
|
||||
BYTE_ORDER_PARAMETER: current_device_config.get(BYTE_ORDER_PARAMETER,
|
||||
self.__byte_order),
|
||||
device.byte_order),
|
||||
WORD_ORDER_PARAMETER: current_device_config.get(WORD_ORDER_PARAMETER,
|
||||
self.__word_order)
|
||||
device.word_order)
|
||||
}, device_responses))
|
||||
|
||||
except ConnectionException:
|
||||
time.sleep(5)
|
||||
sleep(5)
|
||||
log.error("Connection lost! Reconnecting...")
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
|
||||
def on_attributes_update(self, content):
|
||||
try:
|
||||
for attribute_updates_command_config in \
|
||||
self.__devices[content[DEVICE_SECTION_PARAMETER]][CONFIG_SECTION_PARAMETER]["attributeUpdates"]:
|
||||
for attribute_updated in content[DATA_PARAMETER]:
|
||||
if attribute_updates_command_config[TAG_PARAMETER] == attribute_updated:
|
||||
to_process = {
|
||||
DEVICE_SECTION_PARAMETER: content[DEVICE_SECTION_PARAMETER],
|
||||
DATA_PARAMETER: {
|
||||
RPC_METHOD_PARAMETER: attribute_updated,
|
||||
RPC_PARAMS_PARAMETER: content[DATA_PARAMETER][attribute_updated]
|
||||
}
|
||||
}
|
||||
self.__process_rpc_request(to_process, attribute_updates_command_config)
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
|
||||
def __connect_to_current_master(self, device=None):
|
||||
# TODO: write documentation
|
||||
connect_attempt_count = 5
|
||||
connect_attempt_time_ms = 100
|
||||
wait_after_failed_attempts_ms = 300000
|
||||
# if device is None:
|
||||
# device = list(self.__devices.keys())[0]
|
||||
if self.__devices[device].get(MASTER_PARAMETER) is None:
|
||||
self.__devices[device][MASTER_PARAMETER], self.__devices[device][
|
||||
AVAILABLE_FUNCTIONS_PARAMETER] = self.__configure_master(
|
||||
self.__devices[device][CONFIG_SECTION_PARAMETER])
|
||||
if self.__devices[device][MASTER_PARAMETER] != self.__current_master:
|
||||
self.__current_master = self.__devices[device][MASTER_PARAMETER]
|
||||
self.__available_functions = self.__devices[device][AVAILABLE_FUNCTIONS_PARAMETER]
|
||||
connect_attempt_count = self.__devices[device][CONFIG_SECTION_PARAMETER].get(CONNECT_ATTEMPT_COUNT_PARAMETER,
|
||||
connect_attempt_count)
|
||||
|
||||
if device.config.get('master') is None:
|
||||
device.config['master'], device.config['available_functions'] = self.__configure_master(device.config)
|
||||
|
||||
if connect_attempt_count < 1:
|
||||
connect_attempt_count = 1
|
||||
connect_attempt_time_ms = self.__devices[device][CONFIG_SECTION_PARAMETER].get(
|
||||
CONNECT_ATTEMPT_TIME_MS_PARAMETER, connect_attempt_time_ms)
|
||||
|
||||
connect_attempt_time_ms = device.config.get('connectAttemptTimeMs', connect_attempt_time_ms)
|
||||
|
||||
if connect_attempt_time_ms < 500:
|
||||
connect_attempt_time_ms = 500
|
||||
wait_after_failed_attempts_ms = self.__devices[device][CONFIG_SECTION_PARAMETER].get(
|
||||
WAIT_AFTER_FAILED_ATTEMPTS_MS_PARAMETER, wait_after_failed_attempts_ms)
|
||||
|
||||
wait_after_failed_attempts_ms = device.config.get('waitAfterFailedAttemptsMs', wait_after_failed_attempts_ms)
|
||||
|
||||
if wait_after_failed_attempts_ms < 1000:
|
||||
wait_after_failed_attempts_ms = 1000
|
||||
current_time = time.time() * 1000
|
||||
if not self.__current_master.is_socket_open():
|
||||
if self.__devices[device][CONNECTION_ATTEMPT_PARAMETER] >= connect_attempt_count and \
|
||||
current_time - self.__devices[device][
|
||||
LAST_CONNECTION_ATTEMPT_TIME_PARAMETER] >= wait_after_failed_attempts_ms:
|
||||
self.__devices[device][CONNECTION_ATTEMPT_PARAMETER] = 0
|
||||
while not self.__current_master.is_socket_open() \
|
||||
and self.__devices[device][CONNECTION_ATTEMPT_PARAMETER] < connect_attempt_count \
|
||||
and current_time - self.__devices[device].get(LAST_CONNECTION_ATTEMPT_TIME_PARAMETER,
|
||||
|
||||
current_time = time() * 1000
|
||||
|
||||
if not device.config['master'].is_socket_open():
|
||||
if device.config['connection_attempt'] >= connect_attempt_count and current_time - device.config[
|
||||
'last_connection_attempt_time'] >= wait_after_failed_attempts_ms:
|
||||
device.config['connection_attempt'] = 0
|
||||
|
||||
while not device.config['master'].is_socket_open() \
|
||||
and device.config['connection_attempt'] < connect_attempt_count \
|
||||
and current_time - device.config.get('last_connection_attempt_time',
|
||||
0) >= connect_attempt_time_ms:
|
||||
self.__devices[device][CONNECTION_ATTEMPT_PARAMETER] = self.__devices[device][
|
||||
CONNECTION_ATTEMPT_PARAMETER] + 1
|
||||
self.__devices[device][LAST_CONNECTION_ATTEMPT_TIME_PARAMETER] = current_time
|
||||
device.config['connection_attempt'] = device.config[
|
||||
'connection_attempt'] + 1
|
||||
device.config['last_connection_attempt_time'] = current_time
|
||||
log.debug("Modbus trying connect to %s", device)
|
||||
self.__current_master.connect()
|
||||
if self.__devices[device][CONNECTION_ATTEMPT_PARAMETER] == connect_attempt_count:
|
||||
device.config['master'].connect()
|
||||
|
||||
if device.config['connection_attempt'] == connect_attempt_count:
|
||||
log.warn("Maximum attempt count (%i) for device \"%s\" - encountered.", connect_attempt_count,
|
||||
device)
|
||||
# time.sleep(connect_attempt_time_ms / 1000)
|
||||
# if not self.__current_master.is_socket_open():
|
||||
if self.__devices[device][CONNECTION_ATTEMPT_PARAMETER] >= 0 and self.__current_master.is_socket_open():
|
||||
self.__devices[device][CONNECTION_ATTEMPT_PARAMETER] = 0
|
||||
self.__devices[device][LAST_CONNECTION_ATTEMPT_TIME_PARAMETER] = current_time
|
||||
# log.debug("Modbus connected to device %s.", device)
|
||||
|
||||
def __configure_master(self, config=None):
|
||||
current_config = self.__config if config is None else config
|
||||
if device.config['connection_attempt'] >= 0 and device.config['master'].is_socket_open():
|
||||
device.config['connection_attempt'] = 0
|
||||
device.config['last_connection_attempt_time'] = current_time
|
||||
|
||||
master_config = dict()
|
||||
master_config["host"] = current_config[HOST_PARAMETER] if current_config.get(
|
||||
HOST_PARAMETER) is not None else self.__config.get(HOST_PARAMETER, "localhost")
|
||||
try:
|
||||
master_config["port"] = int(current_config[PORT_PARAMETER]) if current_config.get(
|
||||
PORT_PARAMETER) is not None else self.__config.get(int(PORT_PARAMETER), 502)
|
||||
except ValueError:
|
||||
master_config["port"] = current_config[PORT_PARAMETER] if current_config.get(
|
||||
PORT_PARAMETER) is not None else self.__config.get(PORT_PARAMETER, 502)
|
||||
master_config["baudrate"] = current_config[BAUDRATE_PARAMETER] if current_config.get(
|
||||
BAUDRATE_PARAMETER) is not None else self.__config.get(BAUDRATE_PARAMETER, 19200)
|
||||
master_config["timeout"] = current_config[TIMEOUT_PARAMETER] if current_config.get(
|
||||
TIMEOUT_PARAMETER) is not None else self.__config.get(TIMEOUT_PARAMETER, 35)
|
||||
master_config["method"] = current_config[METHOD_PARAMETER] if current_config.get(
|
||||
METHOD_PARAMETER) is not None else self.__config.get(METHOD_PARAMETER, "rtu")
|
||||
master_config["stopbits"] = current_config[STOPBITS_PARAMETER] if current_config.get(
|
||||
STOPBITS_PARAMETER) is not None else self.__config.get(STOPBITS_PARAMETER, Defaults.Stopbits)
|
||||
master_config["bytesize"] = current_config[BYTESIZE_PARAMETER] if current_config.get(
|
||||
BYTESIZE_PARAMETER) is not None else self.__config.get(BYTESIZE_PARAMETER, Defaults.Bytesize)
|
||||
master_config["parity"] = current_config[PARITY_PARAMETER] if current_config.get(
|
||||
PARITY_PARAMETER) is not None else self.__config.get(PARITY_PARAMETER, Defaults.Parity)
|
||||
master_config["strict"] = current_config[STRICT_PARAMETER] if current_config.get(
|
||||
STRICT_PARAMETER) is not None else self.__config.get(STRICT_PARAMETER, True)
|
||||
master_config["retries"] = current_config[RETRIES_PARAMETER] if current_config.get(
|
||||
RETRIES_PARAMETER) is not None else self.__config.get(RETRIES_PARAMETER, 3)
|
||||
master_config["retry_on_empty"] = current_config[RETRY_ON_EMPTY_PARAMETER] if current_config.get(
|
||||
RETRY_ON_EMPTY_PARAMETER) is not None else self.__config.get(RETRY_ON_EMPTY_PARAMETER, True)
|
||||
master_config["retry_on_invalid"] = current_config[RETRY_ON_INVALID_PARAMETER] if current_config.get(
|
||||
RETRY_ON_INVALID_PARAMETER) is not None else self.__config.get(RETRY_ON_INVALID_PARAMETER, True)
|
||||
master_config["rtu"] = ModbusRtuFramer if current_config.get(METHOD_PARAMETER) == "rtu" or (
|
||||
current_config.get(METHOD_PARAMETER) is None and self.__config.get(
|
||||
METHOD_PARAMETER) == "rtu") else ModbusSocketFramer
|
||||
if self.__previous_master_config != master_config:
|
||||
self.__previous_master_config = master_config
|
||||
if current_config.get(TYPE_PARAMETER) == 'tcp' or (
|
||||
current_config.get(TYPE_PARAMETER) is None and self.__config.get(TYPE_PARAMETER) == "tcp"):
|
||||
master = ModbusTcpClient(master_config["host"], master_config["port"], master_config["rtu"],
|
||||
timeout=master_config["timeout"],
|
||||
retry_on_empty=master_config["retry_on_empty"],
|
||||
retry_on_invalid=master_config["retry_on_invalid"],
|
||||
retries=master_config["retries"])
|
||||
elif current_config.get(TYPE_PARAMETER) == 'udp' or (
|
||||
current_config.get(TYPE_PARAMETER) is None and self.__config.get(TYPE_PARAMETER) == "udp"):
|
||||
master = ModbusUdpClient(master_config["host"], master_config["port"], master_config["rtu"],
|
||||
timeout=master_config["timeout"],
|
||||
retry_on_empty=master_config["retry_on_empty"],
|
||||
retry_on_invalid=master_config["retry_on_invalid"],
|
||||
retries=master_config["retries"])
|
||||
elif current_config.get(TYPE_PARAMETER) == 'serial' or (
|
||||
current_config.get(TYPE_PARAMETER) is None and self.__config.get(TYPE_PARAMETER) == "serial"):
|
||||
master = ModbusSerialClient(method=master_config["method"],
|
||||
port=master_config["port"],
|
||||
timeout=master_config["timeout"],
|
||||
retry_on_empty=master_config["retry_on_empty"],
|
||||
retry_on_invalid=master_config["retry_on_invalid"],
|
||||
retries=master_config["retries"],
|
||||
baudrate=master_config["baudrate"],
|
||||
stopbits=master_config["stopbits"],
|
||||
bytesize=master_config["bytesize"],
|
||||
parity=master_config["parity"],
|
||||
strict=master_config["strict"])
|
||||
@staticmethod
|
||||
def __configure_master(config):
|
||||
current_config = config
|
||||
current_config["rtu"] = FRAMER_TYPE[current_config['method']]
|
||||
|
||||
if current_config.get('type') == 'tcp':
|
||||
master = ModbusTcpClient(current_config["host"],
|
||||
current_config["port"],
|
||||
current_config["rtu"],
|
||||
timeout=current_config["timeout"],
|
||||
retry_on_empty=current_config["retry_on_empty"],
|
||||
retry_on_invalid=current_config["retry_on_invalid"],
|
||||
retries=current_config["retries"])
|
||||
elif current_config.get(TYPE_PARAMETER) == 'udp':
|
||||
master = ModbusUdpClient(current_config["host"],
|
||||
current_config["port"],
|
||||
current_config["rtu"],
|
||||
timeout=current_config["timeout"],
|
||||
retry_on_empty=current_config["retry_on_empty"],
|
||||
retry_on_invalid=current_config["retry_on_invalid"],
|
||||
retries=current_config["retries"])
|
||||
elif current_config.get(TYPE_PARAMETER) == 'serial':
|
||||
master = ModbusSerialClient(method=current_config["method"],
|
||||
port=current_config["port"],
|
||||
timeout=current_config["timeout"],
|
||||
retry_on_empty=current_config["retry_on_empty"],
|
||||
retry_on_invalid=current_config["retry_on_invalid"],
|
||||
retries=current_config["retries"],
|
||||
baudrate=current_config["baudrate"],
|
||||
stopbits=current_config["stopbits"],
|
||||
bytesize=current_config["bytesize"],
|
||||
parity=current_config["parity"],
|
||||
strict=current_config["strict"])
|
||||
else:
|
||||
raise Exception("Invalid Modbus transport type.")
|
||||
else:
|
||||
master = self.__current_master
|
||||
|
||||
available_functions = {
|
||||
1: master.read_coils,
|
||||
2: master.read_discrete_inputs,
|
||||
@@ -370,55 +382,79 @@ class ModbusConnector(Connector, threading.Thread):
|
||||
return master, available_functions
|
||||
|
||||
def __stop_connections_to_masters(self):
|
||||
for device in self.__devices:
|
||||
if self.__devices[device].get(MASTER_PARAMETER) is not None:
|
||||
self.__devices[device][MASTER_PARAMETER].close()
|
||||
for slave in self.__slaves:
|
||||
if slave.config.get('master') is not None and slave.config.get('master').is_socket_open():
|
||||
slave.config['master'].close()
|
||||
|
||||
def __function_to_device(self, config, unit_id):
|
||||
function_code = config.get(FUNCTION_CODE_PARAMETER)
|
||||
@staticmethod
|
||||
def __function_to_device(device, config):
|
||||
function_code = config.get('functionCode')
|
||||
result = None
|
||||
if function_code in (1, 2, 3, 4):
|
||||
result = self.__available_functions[function_code](address=config[ADDRESS_PARAMETER],
|
||||
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
||||
count=config.get(OBJECTS_COUNT_PARAMETER,
|
||||
config.get("registersCount",
|
||||
config.get("registerCount",
|
||||
config.get(
|
||||
"registerCount",
|
||||
1))),
|
||||
unit=unit_id)
|
||||
unit=device.config['unitId'])
|
||||
elif function_code in (5, 6):
|
||||
result = self.__available_functions[function_code](address=config[ADDRESS_PARAMETER],
|
||||
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
||||
value=config[PAYLOAD_PARAMETER],
|
||||
unit=unit_id)
|
||||
unit=device.config['unitId'])
|
||||
elif function_code in (15, 16):
|
||||
result = self.__available_functions[function_code](address=config[ADDRESS_PARAMETER],
|
||||
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
||||
values=config[PAYLOAD_PARAMETER],
|
||||
unit=unit_id)
|
||||
unit=device.config['unitId'])
|
||||
else:
|
||||
log.error("Unknown Modbus function with code: %i", function_code)
|
||||
log.error("Unknown Modbus function with code: %s", function_code)
|
||||
|
||||
log.debug("With result %s", str(result))
|
||||
|
||||
if "Exception" in str(result):
|
||||
log.exception(result)
|
||||
|
||||
return result
|
||||
|
||||
def on_attributes_update(self, content):
|
||||
try:
|
||||
device = tuple(filter(lambda slave: slave.name == content[DEVICE_SECTION_PARAMETER], self.__slaves))[0]
|
||||
|
||||
for attribute_updates_command_config in device.config['attributeUpdates']:
|
||||
for attribute_updated in content[DATA_PARAMETER]:
|
||||
if attribute_updates_command_config[TAG_PARAMETER] == attribute_updated:
|
||||
to_process = {
|
||||
DEVICE_SECTION_PARAMETER: content[DEVICE_SECTION_PARAMETER],
|
||||
DATA_PARAMETER: {
|
||||
RPC_METHOD_PARAMETER: attribute_updated,
|
||||
RPC_PARAMS_PARAMETER: content[DATA_PARAMETER][attribute_updated]
|
||||
}
|
||||
}
|
||||
self.__process_rpc_request(to_process, attribute_updates_command_config)
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
|
||||
def server_side_rpc_handler(self, server_rpc_request):
|
||||
try:
|
||||
if server_rpc_request.get(DEVICE_SECTION_PARAMETER) is not None:
|
||||
|
||||
log.debug("Modbus connector received rpc request for %s with server_rpc_request: %s",
|
||||
server_rpc_request[DEVICE_SECTION_PARAMETER],
|
||||
server_rpc_request)
|
||||
if isinstance(self.__devices[server_rpc_request[DEVICE_SECTION_PARAMETER]][CONFIG_SECTION_PARAMETER][
|
||||
RPC_SECTION], dict):
|
||||
rpc_command_config = \
|
||||
self.__devices[server_rpc_request[DEVICE_SECTION_PARAMETER]][CONFIG_SECTION_PARAMETER][
|
||||
RPC_SECTION].get(
|
||||
device = tuple(
|
||||
filter(
|
||||
lambda slave: slave.name == server_rpc_request[DEVICE_SECTION_PARAMETER], self.__slaves
|
||||
)
|
||||
)[0]
|
||||
|
||||
if isinstance(device.config[RPC_SECTION], dict):
|
||||
rpc_command_config = device.config[RPC_SECTION].get(
|
||||
server_rpc_request[DATA_PARAMETER][RPC_METHOD_PARAMETER])
|
||||
|
||||
if rpc_command_config is not None:
|
||||
self.__process_rpc_request(server_rpc_request, rpc_command_config)
|
||||
elif isinstance(self.__devices[server_rpc_request[DEVICE_SECTION_PARAMETER]][CONFIG_SECTION_PARAMETER][
|
||||
RPC_SECTION], list):
|
||||
for rpc_command_config in \
|
||||
self.__devices[server_rpc_request[DEVICE_SECTION_PARAMETER]][CONFIG_SECTION_PARAMETER][
|
||||
RPC_SECTION]:
|
||||
|
||||
elif isinstance(device.config[RPC_SECTION], list):
|
||||
for rpc_command_config in device.config[RPC_SECTION]:
|
||||
if rpc_command_config[TAG_PARAMETER] == server_rpc_request[DATA_PARAMETER][
|
||||
RPC_METHOD_PARAMETER]:
|
||||
self.__process_rpc_request(server_rpc_request, rpc_command_config)
|
||||
@@ -438,45 +474,41 @@ class ModbusConnector(Connector, threading.Thread):
|
||||
|
||||
def __process_rpc_request(self, content, rpc_command_config):
|
||||
if rpc_command_config is not None:
|
||||
rpc_command_config[UNIT_ID_PARAMETER] = \
|
||||
self.__devices[content[DEVICE_SECTION_PARAMETER]][CONFIG_SECTION_PARAMETER][UNIT_ID_PARAMETER]
|
||||
self.__connect_to_current_master(content[DEVICE_SECTION_PARAMETER])
|
||||
# if rpc_command_config.get('bit') is not None:
|
||||
# rpc_command_config[FUNCTION_CODE_PARAMETER] = 6
|
||||
device = tuple(filter(lambda slave: slave.name == content[DEVICE_SECTION_PARAMETER], self.__slaves))[0]
|
||||
rpc_command_config[UNIT_ID_PARAMETER] = device.config['unitId']
|
||||
self.__connect_to_current_master(device)
|
||||
|
||||
if rpc_command_config.get(FUNCTION_CODE_PARAMETER) in (5, 6, 15, 16):
|
||||
rpc_command_config[PAYLOAD_PARAMETER] = self.__devices[content[DEVICE_SECTION_PARAMETER]][
|
||||
rpc_command_config[PAYLOAD_PARAMETER] = device.config[
|
||||
DOWNLINK_PREFIX + CONVERTER_PARAMETER].convert(
|
||||
rpc_command_config, content)
|
||||
response = None
|
||||
|
||||
try:
|
||||
response = self.__function_to_device(rpc_command_config, rpc_command_config[UNIT_ID_PARAMETER])
|
||||
response = self.__function_to_device(device, rpc_command_config)
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
response = e
|
||||
|
||||
if isinstance(response, (ReadRegistersResponseBase, ReadBitsResponseBase)):
|
||||
to_converter = {
|
||||
RPC_SECTION: {content[DATA_PARAMETER][RPC_METHOD_PARAMETER]: {"data_sent": rpc_command_config,
|
||||
"input_data": response}}}
|
||||
response = self.__devices[content[DEVICE_SECTION_PARAMETER]][
|
||||
response = device.config[
|
||||
UPLINK_PREFIX + CONVERTER_PARAMETER].convert(
|
||||
config={**self.__devices[content[DEVICE_SECTION_PARAMETER]][CONFIG_SECTION_PARAMETER],
|
||||
BYTE_ORDER_PARAMETER: self.__devices[content[DEVICE_SECTION_PARAMETER]][
|
||||
CONFIG_SECTION_PARAMETER].get(BYTE_ORDER_PARAMETER,
|
||||
self.__byte_order),
|
||||
WORD_ORDER_PARAMETER: self.__devices[content[DEVICE_SECTION_PARAMETER]][
|
||||
CONFIG_SECTION_PARAMETER].get(WORD_ORDER_PARAMETER,
|
||||
self.__word_order)
|
||||
config={**device.config,
|
||||
BYTE_ORDER_PARAMETER: device.byte_order,
|
||||
WORD_ORDER_PARAMETER: device.word_order
|
||||
},
|
||||
data=to_converter)
|
||||
log.debug("Received RPC method: %s, result: %r", content[DATA_PARAMETER][RPC_METHOD_PARAMETER],
|
||||
response)
|
||||
# response = {"success": response}
|
||||
elif isinstance(response, (WriteMultipleRegistersResponse,
|
||||
WriteMultipleCoilsResponse,
|
||||
WriteSingleCoilResponse,
|
||||
WriteSingleRegisterResponse)):
|
||||
log.debug("Write %r", str(response))
|
||||
response = {"success": True}
|
||||
|
||||
if content.get(RPC_ID_PARAMETER) or (
|
||||
content.get(DATA_PARAMETER) is not None and content[DATA_PARAMETER].get(RPC_ID_PARAMETER)):
|
||||
if isinstance(response, Exception):
|
||||
@@ -487,4 +519,5 @@ class ModbusConnector(Connector, threading.Thread):
|
||||
self.__gateway.send_rpc_reply(content[DEVICE_SECTION_PARAMETER],
|
||||
content[DATA_PARAMETER][RPC_ID_PARAMETER],
|
||||
response)
|
||||
|
||||
log.debug("%r", response)
|
||||
|
||||
115
thingsboard_gateway/connectors/modbus/slave.py
Normal file
115
thingsboard_gateway/connectors/modbus/slave.py
Normal file
@@ -0,0 +1,115 @@
|
||||
# Copyright 2021. ThingsBoard
|
||||
#
|
||||
# Licensed under the Apache License, Version 2.0 (the "License");
|
||||
# you may not use this file except in compliance with the License.
|
||||
# You may obtain a copy of the License at
|
||||
#
|
||||
# http://www.apache.org/licenses/LICENSE-2.0
|
||||
#
|
||||
# Unless required by applicable law or agreed to in writing, software
|
||||
# distributed under the License is distributed on an "AS IS" BASIS,
|
||||
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
||||
# See the License for the specific language governing permissions and
|
||||
# limitations under the License.
|
||||
|
||||
from threading import Thread
|
||||
from time import time, sleep
|
||||
|
||||
from pymodbus.constants import Defaults
|
||||
|
||||
from thingsboard_gateway.connectors.modbus.constants import *
|
||||
from thingsboard_gateway.connectors.connector import log
|
||||
from thingsboard_gateway.connectors.modbus.bytes_modbus_uplink_converter import BytesModbusUplinkConverter
|
||||
from thingsboard_gateway.connectors.modbus.bytes_modbus_downlink_converter import BytesModbusDownlinkConverter
|
||||
from thingsboard_gateway.tb_utility.tb_loader import TBModuleLoader
|
||||
|
||||
|
||||
class Slave(Thread):
|
||||
def __init__(self, **kwargs):
|
||||
super().__init__()
|
||||
self.timeout = kwargs.get('timeout')
|
||||
self.name = kwargs['deviceName']
|
||||
self.poll_period = kwargs['pollPeriod'] / 1000
|
||||
|
||||
self.byte_order = kwargs['byteOrder']
|
||||
self.word_order = kwargs.get('wordOrder')
|
||||
self.config = {
|
||||
'unitId': kwargs['unitId'],
|
||||
'deviceType': kwargs.get('deviceType', 'default'),
|
||||
'type': kwargs['type'],
|
||||
'host': kwargs.get('host'),
|
||||
'port': kwargs['port'],
|
||||
'timeout': kwargs.get('timeout', 35),
|
||||
'stopbits': kwargs.get('stopbits', Defaults.Stopbits),
|
||||
'bytesize': kwargs.get('bytesize', Defaults.Bytesize),
|
||||
'parity': kwargs.get('parity', Defaults.Parity),
|
||||
'strict': kwargs.get('strict', True),
|
||||
'retries': kwargs.get('retries', 3),
|
||||
'connection_attempt': 0,
|
||||
'last_connection_attempt_time': 0,
|
||||
'sendDataOnlyOnChange': kwargs.get('sendDataOnlyOnChange', False),
|
||||
'waitAfterFailedAttemptsMs': kwargs.get('waitAfterFailedAttemptsMs', 0),
|
||||
'connectAttemptTimeMs': kwargs.get('connectAttemptTimeMs', 0),
|
||||
'retry_on_empty': kwargs.get('retry_on_empty', True),
|
||||
'retry_on_invalid': kwargs.get('retry_on_invalid', True),
|
||||
'method': kwargs.get('method', 'rtu'),
|
||||
'baudrate': kwargs.get('baudrate', 19200),
|
||||
'attributes': kwargs.get('attributes', []),
|
||||
'timeseries': kwargs.get('timeseries', []),
|
||||
'attributeUpdates': kwargs.get('attributeUpdates', []),
|
||||
'rpc': kwargs.get('rpc', []),
|
||||
'last_attributes': {},
|
||||
'last_telemetry': {}
|
||||
}
|
||||
|
||||
self.__load_converters(kwargs['connector'], kwargs['gateway'])
|
||||
|
||||
self.callback = kwargs['callback']
|
||||
|
||||
self.last_polled_time = None
|
||||
self.daemon = True
|
||||
|
||||
self.start()
|
||||
|
||||
def timer(self):
|
||||
self.callback(self)
|
||||
self.last_polled_time = time()
|
||||
|
||||
while True:
|
||||
if time() - self.last_polled_time >= self.poll_period:
|
||||
self.callback(self)
|
||||
self.last_polled_time = time()
|
||||
|
||||
sleep(.2)
|
||||
|
||||
def run(self):
|
||||
self.timer()
|
||||
|
||||
def get_name(self):
|
||||
return self.name
|
||||
|
||||
def __load_converters(self, connector, gateway):
|
||||
try:
|
||||
if self.config.get(UPLINK_PREFIX + CONVERTER_PARAMETER) is not None:
|
||||
converter = TBModuleLoader.import_module(connector.connector_type,
|
||||
self.config[UPLINK_PREFIX + CONVERTER_PARAMETER])(self)
|
||||
else:
|
||||
converter = BytesModbusUplinkConverter({**self.config, 'deviceName': self.name})
|
||||
|
||||
if self.config.get(DOWNLINK_PREFIX + CONVERTER_PARAMETER) is not None:
|
||||
downlink_converter = TBModuleLoader.import_module(connector.connector_type, self.config[
|
||||
DOWNLINK_PREFIX + CONVERTER_PARAMETER])(self)
|
||||
else:
|
||||
downlink_converter = BytesModbusDownlinkConverter(self.config)
|
||||
|
||||
if self.name not in gateway.get_devices():
|
||||
gateway.add_device(self.name, {CONNECTOR_PARAMETER: connector},
|
||||
device_type=self.config.get(DEVICE_TYPE_PARAMETER))
|
||||
|
||||
self.config[UPLINK_PREFIX + CONVERTER_PARAMETER] = converter
|
||||
self.config[DOWNLINK_PREFIX + CONVERTER_PARAMETER] = downlink_converter
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
|
||||
def __str__(self):
|
||||
return f'{self.name}'
|
||||
@@ -153,7 +153,6 @@ class TBGatewayService:
|
||||
self.connectors_configs = {}
|
||||
self.__remote_configurator = None
|
||||
self.__request_config_after_connect = False
|
||||
self.__connected_devices = {}
|
||||
self.__load_persistent_devices()
|
||||
self.__init_remote_configuration()
|
||||
self.__grpc_config = self.__config.get('grpc')
|
||||
@@ -898,9 +897,17 @@ class TBGatewayService:
|
||||
log.debug("Loaded devices:\n %s", devices)
|
||||
for device_name in devices:
|
||||
try:
|
||||
if self.available_connectors.get(devices[device_name]):
|
||||
if not isinstance(devices[device_name], tuple):
|
||||
open(self._config_dir + self.__connected_devices_file, 'w').close()
|
||||
log.debug("Old connected_devices file, new file will be created")
|
||||
return
|
||||
if self.available_connectors.get(devices[device_name][0]):
|
||||
self.__connected_devices[device_name] = {
|
||||
"connector": self.available_connectors[devices[device_name]]}
|
||||
"connector": self.available_connectors[devices[device_name][0]],
|
||||
"device_type": devices[device_name][1]}
|
||||
self.__saved_devices[device_name] = {
|
||||
"connector": self.available_connectors[devices[device_name][0]],
|
||||
"device_type": devices[device_name][1]}
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
continue
|
||||
@@ -914,7 +921,7 @@ class TBGatewayService:
|
||||
data_to_save = {}
|
||||
for device in self.__connected_devices:
|
||||
if self.__connected_devices[device]["connector"] is not None:
|
||||
data_to_save[device] = self.__connected_devices[device]["connector"].get_name()
|
||||
data_to_save[device] = (self.__connected_devices[device]["connector"].get_name(), self.__connected_devices[device]["device_type"])
|
||||
config_file.write(dumps(data_to_save, indent=2, sort_keys=True))
|
||||
except Exception as e:
|
||||
log.exception(e)
|
||||
|
||||
Reference in New Issue
Block a user