from copy import deepcopy
|
|
from threading import Thread, Lock
|
|
from time import sleep, time
|
|
from queue import Queue
|
|
from random import choice
|
|
from string import ascii_lowercase
|
|
from packaging import version
|
|
|
|
from thingsboard_gateway.tb_utility.tb_utility import TBUtility
|
|
from thingsboard_gateway.tb_utility.tb_logger import init_logger
|
|
|
|
# Try import Pymodbus library or install it and import
|
|
installation_required = False
|
|
required_version = '3.0.0'
|
|
force_install = False
|
|
|
|
try:
|
|
from pymodbus import __version__ as pymodbus_version
|
|
|
|
if version.parse(pymodbus_version) < version.parse(required_version):
|
|
installation_required = True
|
|
|
|
if version.parse(
|
|
pymodbus_version) > version.parse(required_version):
|
|
installation_required = True
|
|
force_install = True
|
|
|
|
except ImportError:
|
|
installation_required = True
|
|
|
|
if installation_required:
|
|
print("Modbus library not found - installing...")
|
|
TBUtility.install_package("pymodbus", "3.0.0", force_install=force_install)
|
|
TBUtility.install_package('pyserial')
|
|
TBUtility.install_package('pyserial-asyncio')
|
|
|
|
try:
|
|
from twisted.internet import reactor
|
|
except ImportError:
|
|
TBUtility.install_package('twisted')
|
|
from twisted.internet import reactor
|
|
|
|
from twisted.internet import reactor
|
|
from pymodbus.bit_write_message import WriteSingleCoilResponse, WriteMultipleCoilsResponse
|
|
from pymodbus.register_write_message import WriteMultipleRegistersResponse, WriteSingleRegisterResponse
|
|
from pymodbus.register_read_message import ReadRegistersResponseBase
|
|
from pymodbus.bit_read_message import ReadBitsResponseBase
|
|
from pymodbus.client import ModbusTcpClient, ModbusTlsClient, ModbusUdpClient, ModbusSerialClient
|
|
from pymodbus.framer.rtu_framer import ModbusRtuFramer
|
|
from pymodbus.framer.socket_framer import ModbusSocketFramer
|
|
from pymodbus.framer.ascii_framer import ModbusAsciiFramer
|
|
from pymodbus.exceptions import ConnectionException, ModbusIOException
|
|
from pymodbus.server import StartTcpServer, StartTlsServer, StartUdpServer, StartSerialServer, ServerStop
|
|
from pymodbus.device import ModbusDeviceIdentification
|
|
from pymodbus.version import version
|
|
from pymodbus.datastore import ModbusSlaveContext, ModbusServerContext
|
|
from pymodbus.datastore import ModbusSparseDataBlock
|
|
from pymodbus.pdu import ExceptionResponse
|
|
|
|
from thingsboard_gateway.connectors.connector import Connector
|
|
from thingsboard_gateway.connectors.modbus.constants import *
|
|
from thingsboard_gateway.connectors.modbus.slave import Slave
|
|
from thingsboard_gateway.connectors.modbus.backward_compability_adapter import BackwardCompatibilityAdapter
|
|
from thingsboard_gateway.connectors.modbus.bytes_modbus_downlink_converter import BytesModbusDownlinkConverter
|
|
|
|
CONVERTED_DATA_SECTIONS = [ATTRIBUTES_PARAMETER, TELEMETRY_PARAMETER]
|
|
FRAMER_TYPE = {
|
|
'rtu': ModbusRtuFramer,
|
|
'socket': ModbusSocketFramer,
|
|
'ascii': ModbusAsciiFramer
|
|
}
|
|
SLAVE_TYPE = {
|
|
'tcp': StartTcpServer,
|
|
'tls': StartTlsServer,
|
|
'udp': StartUdpServer,
|
|
'serial': StartSerialServer
|
|
}
|
|
FUNCTION_TYPE = {
|
|
'coils_initializer': 'co',
|
|
'holding_registers': 'hr',
|
|
'input_registers': 'ir',
|
|
'discrete_inputs': 'di'
|
|
}
|
|
FUNCTION_CODE_WRITE = {
|
|
'holding_registers': (6, 16),
|
|
'coils_initializer': (5, 15)
|
|
}
|
|
FUNCTION_CODE_READ = {
|
|
'holding_registers': 3,
|
|
'coils_initializer': 1,
|
|
'input_registers': 4,
|
|
'discrete_inputs': 2
|
|
}
|
|
|
|
|
|
class ModbusConnector(Connector, Thread):
|
|
process_requests = Queue(-1)
|
|
|
|
def __init__(self, gateway, config, connector_type):
|
|
self.statistics = {STATISTIC_MESSAGE_RECEIVED_PARAMETER: 0,
|
|
STATISTIC_MESSAGE_SENT_PARAMETER: 0}
|
|
super().__init__()
|
|
self.__gateway = gateway
|
|
self._connector_type = connector_type
|
|
self.__log = init_logger(self.__gateway, config.get('name', self.name),
|
|
config.get('logLevel', 'INFO'))
|
|
self.__backward_compatibility_adapter = BackwardCompatibilityAdapter(config, gateway.get_config_path(),
|
|
logger=self.__log)
|
|
self.__config = self.__backward_compatibility_adapter.convert()
|
|
self.setName(self.__config.get("name", 'Modbus Default ' + ''.join(choice(ascii_lowercase) for _ in range(5))))
|
|
|
|
self.__connected = False
|
|
self.__stopped = False
|
|
self.daemon = True
|
|
|
|
self.lock = Lock()
|
|
|
|
self._convert_msg_queue = Queue()
|
|
self._save_msg_queue = Queue()
|
|
|
|
self.__msg_queue = Queue()
|
|
self.__workers_thread_pool = []
|
|
self.__max_msg_number_for_worker = config.get('maxMessageNumberPerWorker', 10)
|
|
self.__max_number_of_workers = config.get('maxNumberOfWorkers', 100)
|
|
|
|
if self.__config.get('slave'):
|
|
self.__slave_thread = Thread(target=self.__configure_and_run_slave, args=(self.__config['slave'],),
|
|
daemon=True, name='Gateway as a slave')
|
|
self.__slave_thread.start()
|
|
|
|
if config['slave'].get('sendDataToThingsBoard', False):
|
|
self.__modify_main_config()
|
|
|
|
self.__slaves = []
|
|
self.__load_slaves()
|
|
|
|
def is_connected(self):
|
|
return self.__connected
|
|
|
|
def open(self):
|
|
self.__stopped = False
|
|
self.start()
|
|
|
|
def get_type(self):
|
|
return self._connector_type
|
|
|
|
def run(self):
|
|
self.__connected = True
|
|
|
|
thread = Thread(target=self.__process_slaves, daemon=True)
|
|
thread.start()
|
|
|
|
while not self.__stopped:
|
|
self.__thread_manager()
|
|
|
|
sleep(.001)
|
|
|
|
def __configure_and_run_slave(self, config):
|
|
identity = None
|
|
if config.get('identity'):
|
|
identity = ModbusDeviceIdentification()
|
|
identity.VendorName = config['identity'].get('vendorName', '')
|
|
identity.ProductCode = config['identity'].get('productCode', '')
|
|
identity.VendorUrl = config['identity'].get('vendorUrl', '')
|
|
identity.ProductName = config['identity'].get('productName', '')
|
|
identity.ModelName = config['identity'].get('ModelName', '')
|
|
identity.MajorMinorRevision = version.short()
|
|
|
|
blocks = {}
|
|
for (key, value) in config.get('values').items():
|
|
values = {}
|
|
converter = BytesModbusDownlinkConverter({}, self.__log)
|
|
for item in value:
|
|
for section in ('attributes', 'timeseries', 'attributeUpdates', 'rpc'):
|
|
for val in item.get(section, []):
|
|
function_code = FUNCTION_CODE_WRITE[key][0] if val['objectsCount'] <= 1 else \
|
|
FUNCTION_CODE_WRITE[key][1]
|
|
converted_value = converter.convert(
|
|
{**val,
|
|
'device': config.get('deviceName', 'Gateway'), 'functionCode': function_code,
|
|
'byteOrder': config['byteOrder'], 'wordOrder': config['wordOrder']},
|
|
{'data': {'params': val['value']}})
|
|
values[val['address'] + 1] = converted_value
|
|
|
|
blocks[FUNCTION_TYPE[key]] = ModbusSparseDataBlock(values)
|
|
|
|
context = ModbusServerContext(slaves=ModbusSlaveContext(**blocks), single=True)
|
|
SLAVE_TYPE[config['type']](context=context, identity=identity,
|
|
address=(config.get('host'), config.get('port')) if (
|
|
config['type'] == 'tcp' or 'udp') else None,
|
|
port=config.get('port') if config['type'] == 'serial' else None,
|
|
framer=FRAMER_TYPE[config['method']], **config.get('security', {}))
|
|
|
|
def __modify_main_config(self):
|
|
config = self.__config['slave']
|
|
|
|
values = config.pop('values')
|
|
device = config
|
|
|
|
for (register, reg_values) in values.items():
|
|
for value in reg_values:
|
|
for section in ('attributes', 'timeseries', 'attributeUpdates', 'rpc'):
|
|
if not device.get(section):
|
|
device[section] = []
|
|
|
|
for item in value.get(section, []):
|
|
device[section].append({**item, 'functionCode': FUNCTION_CODE_READ[
|
|
register] if section not in ('attributeUpdates', 'rpc') else item['functionCode']})
|
|
|
|
self.__config['master']['slaves'].append(device)
|
|
|
|
def __load_slaves(self):
|
|
self.__slaves = [
|
|
Slave(**{**device, 'connector': self, 'gateway': self.__gateway, 'logger': self.__log,
|
|
'callback': ModbusConnector.callback}) for
|
|
device in self.__config.get('master', {'slaves': []}).get('slaves', [])]
|
|
|
|
@classmethod
|
|
def callback(cls, slave):
|
|
cls.process_requests.put(slave)
|
|
|
|
@property
|
|
def connector_type(self):
|
|
return self._connector_type
|
|
|
|
def __thread_manager(self):
|
|
if len(self.__workers_thread_pool) == 0:
|
|
worker = ModbusConnector.ConverterWorker("Main", self._convert_msg_queue, self._save_data, self.__log)
|
|
self.__workers_thread_pool.append(worker)
|
|
worker.start()
|
|
|
|
number_of_needed_threads = round(self._convert_msg_queue.qsize() / self.__max_msg_number_for_worker, 0)
|
|
threads_count = len(self.__workers_thread_pool)
|
|
if number_of_needed_threads > threads_count < self.__max_number_of_workers:
|
|
thread = ModbusConnector.ConverterWorker(
|
|
"Worker " + ''.join(choice(ascii_lowercase) for _ in range(5)), self._convert_msg_queue,
|
|
self._save_data, self.__log)
|
|
self.__workers_thread_pool.append(thread)
|
|
thread.start()
|
|
elif number_of_needed_threads < threads_count and threads_count > 1:
|
|
worker: ModbusConnector.ConverterWorker = self.__workers_thread_pool[-1]
|
|
if not worker.in_progress:
|
|
worker.stopped = True
|
|
self.__workers_thread_pool.remove(worker)
|
|
|
|
def __convert_data(self, params):
|
|
device, current_device_config, config, device_responses = params
|
|
converted_data = {}
|
|
|
|
try:
|
|
converted_data = device.config[UPLINK_PREFIX + CONVERTER_PARAMETER].convert(
|
|
config=config,
|
|
data=device_responses)
|
|
except Exception as e:
|
|
self.__log.error(e)
|
|
|
|
to_send = {DEVICE_NAME_PARAMETER: converted_data[DEVICE_NAME_PARAMETER],
|
|
DEVICE_TYPE_PARAMETER: converted_data[DEVICE_TYPE_PARAMETER],
|
|
TELEMETRY_PARAMETER: [],
|
|
ATTRIBUTES_PARAMETER: []
|
|
}
|
|
|
|
if current_device_config.get('sendDataOnlyOnChange'):
|
|
self.statistics[STATISTIC_MESSAGE_RECEIVED_PARAMETER] += 1
|
|
|
|
for converted_data_section in CONVERTED_DATA_SECTIONS:
|
|
for current_section_dict in converted_data[converted_data_section]:
|
|
for key, value in current_section_dict.items():
|
|
if device.config[LAST_PREFIX + converted_data_section].get(key) is None or \
|
|
device.config[LAST_PREFIX + converted_data_section][key] != value:
|
|
device.config[LAST_PREFIX + converted_data_section][key] = value
|
|
to_send[converted_data_section].append({key: value})
|
|
elif converted_data and current_device_config.get('sendDataOnlyOnChange') is None or \
|
|
not current_device_config.get('sendDataOnlyOnChange'):
|
|
self.statistics[STATISTIC_MESSAGE_RECEIVED_PARAMETER] += 1
|
|
|
|
for converted_data_section in CONVERTED_DATA_SECTIONS:
|
|
device.config[LAST_PREFIX + converted_data_section] = converted_data[
|
|
converted_data_section]
|
|
to_send[converted_data_section] = converted_data[converted_data_section]
|
|
|
|
if to_send.get(ATTRIBUTES_PARAMETER) or to_send.get(TELEMETRY_PARAMETER):
|
|
return to_send
|
|
|
|
def _save_data(self, data):
|
|
self.__gateway.send_to_storage(self.get_name(), data)
|
|
self.statistics[STATISTIC_MESSAGE_SENT_PARAMETER] += 1
|
|
|
|
def close(self):
|
|
self.__stopped = True
|
|
self.__stop_connections_to_masters()
|
|
|
|
# Stop all slaves
|
|
for slave in self.__slaves:
|
|
slave.close()
|
|
|
|
if reactor.running:
|
|
ServerStop()
|
|
self.__log.info('%s has been stopped.', self.get_name())
|
|
self.__log.reset()
|
|
|
|
def get_name(self):
|
|
return self.name
|
|
|
|
def __process_slaves(self):
|
|
while True:
|
|
if not self.__stopped and not ModbusConnector.process_requests.empty():
|
|
device = ModbusConnector.process_requests.get()
|
|
|
|
self.__log.debug("Device connector type: %s", device.config.get(TYPE_PARAMETER))
|
|
if device.config.get(TYPE_PARAMETER).lower() == 'serial':
|
|
self.lock.acquire()
|
|
|
|
device_responses = {'timeseries': {}, 'attributes': {}}
|
|
current_device_config = {}
|
|
try:
|
|
for config_section in device_responses:
|
|
if device.config.get(config_section) is not None and len(device.config.get(config_section)):
|
|
current_device_config = device.config
|
|
|
|
self.__connect_to_current_master(device)
|
|
|
|
if not device.config['master'].is_socket_open() or not len(
|
|
current_device_config[config_section]):
|
|
error = 'Socket is closed' if not device.config[
|
|
'master'].is_socket_open() else 'Config is invalid'
|
|
self.__log.error(error)
|
|
continue
|
|
|
|
# Reading data from device
|
|
for interested_data in range(len(current_device_config[config_section])):
|
|
current_data = deepcopy(current_device_config[config_section][interested_data])
|
|
current_data[DEVICE_NAME_PARAMETER] = device.name
|
|
input_data = self.__function_to_device(device, current_data)
|
|
|
|
# due to issue #1056
|
|
if isinstance(input_data, ModbusIOException) or isinstance(input_data, ExceptionResponse):
|
|
device.config.pop('master', None)
|
|
self.__connect_to_current_master(device)
|
|
break
|
|
|
|
device_responses[config_section][current_data[TAG_PARAMETER]] = {
|
|
"data_sent": current_data,
|
|
"input_data": input_data}
|
|
|
|
self.__log.debug("Checking %s for device %s", config_section, device)
|
|
self.__log.debug('Device response: ', device_responses)
|
|
|
|
if device_responses.get('timeseries') or device_responses.get('attributes'):
|
|
self._convert_msg_queue.put((self.__convert_data, (device, current_device_config, {
|
|
**current_device_config,
|
|
BYTE_ORDER_PARAMETER: current_device_config.get(BYTE_ORDER_PARAMETER,
|
|
device.byte_order),
|
|
WORD_ORDER_PARAMETER: current_device_config.get(WORD_ORDER_PARAMETER,
|
|
device.word_order)
|
|
}, device_responses)))
|
|
|
|
except ConnectionException:
|
|
sleep(5)
|
|
self.__log.error("Connection lost! Reconnecting...")
|
|
except Exception as e:
|
|
self.__log.exception(e)
|
|
|
|
# Release mutex if "serial" type only
|
|
if device.config.get(TYPE_PARAMETER) == 'serial':
|
|
self.lock.release()
|
|
|
|
sleep(.001)
|
|
|
|
def __connect_to_current_master(self, device=None):
|
|
# TODO: write documentation
|
|
connect_attempt_count = 5
|
|
connect_attempt_time_ms = 100
|
|
wait_after_failed_attempts_ms = 300000
|
|
|
|
if device.config.get('master') is None:
|
|
device.config['master'], device.config['available_functions'] = self.__configure_master(device.config)
|
|
|
|
if connect_attempt_count < 1:
|
|
connect_attempt_count = 1
|
|
|
|
connect_attempt_time_ms = device.config.get('connectAttemptTimeMs', connect_attempt_time_ms)
|
|
|
|
if connect_attempt_time_ms < 500:
|
|
connect_attempt_time_ms = 500
|
|
|
|
wait_after_failed_attempts_ms = device.config.get('waitAfterFailedAttemptsMs', wait_after_failed_attempts_ms)
|
|
|
|
if wait_after_failed_attempts_ms < 1000:
|
|
wait_after_failed_attempts_ms = 1000
|
|
|
|
current_time = time() * 1000
|
|
|
|
if not device.config['master'].is_socket_open():
|
|
if device.config['connection_attempt'] >= connect_attempt_count and current_time - device.config[
|
|
'last_connection_attempt_time'] >= wait_after_failed_attempts_ms:
|
|
device.config['connection_attempt'] = 0
|
|
|
|
while not device.config['master'].is_socket_open() \
|
|
and device.config['connection_attempt'] < connect_attempt_count \
|
|
and current_time - device.config.get('last_connection_attempt_time',
|
|
0) >= connect_attempt_time_ms:
|
|
device.config['connection_attempt'] = device.config[
|
|
'connection_attempt'] + 1
|
|
device.config['last_connection_attempt_time'] = current_time
|
|
self.__log.debug("Modbus trying connect to %s", device)
|
|
device.config['master'].connect()
|
|
|
|
if device.config['connection_attempt'] == connect_attempt_count:
|
|
self.__log.warn("Maximum attempt count (%i) for device \"%s\" - encountered.",
|
|
connect_attempt_count,
|
|
device)
|
|
|
|
if device.config['connection_attempt'] >= 0 and device.config['master'].is_socket_open():
|
|
device.config['connection_attempt'] = 0
|
|
device.config['last_connection_attempt_time'] = current_time
|
|
|
|
@staticmethod
|
|
def __configure_master(config):
|
|
current_config = config
|
|
current_config["rtu"] = FRAMER_TYPE[current_config['method']]
|
|
|
|
if current_config.get('type') == 'tcp' and current_config.get('tls'):
|
|
master = ModbusTlsClient(current_config["host"],
|
|
current_config["port"],
|
|
current_config["rtu"],
|
|
timeout=current_config["timeout"],
|
|
retry_on_empty=current_config["retry_on_empty"],
|
|
retry_on_invalid=current_config["retry_on_invalid"],
|
|
retries=current_config["retries"],
|
|
**current_config['tls'])
|
|
elif current_config.get('type') == 'tcp':
|
|
master = ModbusTcpClient(current_config["host"],
|
|
current_config["port"],
|
|
current_config["rtu"],
|
|
timeout=current_config["timeout"],
|
|
retry_on_empty=current_config["retry_on_empty"],
|
|
retry_on_invalid=current_config["retry_on_invalid"],
|
|
retries=current_config["retries"])
|
|
elif current_config.get(TYPE_PARAMETER) == 'udp':
|
|
master = ModbusUdpClient(current_config["host"],
|
|
current_config["port"],
|
|
current_config["rtu"],
|
|
timeout=current_config["timeout"],
|
|
retry_on_empty=current_config["retry_on_empty"],
|
|
retry_on_invalid=current_config["retry_on_invalid"],
|
|
retries=current_config["retries"])
|
|
elif current_config.get(TYPE_PARAMETER) == 'serial':
|
|
master = ModbusSerialClient(method=current_config["method"],
|
|
port=current_config["port"],
|
|
timeout=current_config["timeout"],
|
|
retry_on_empty=current_config["retry_on_empty"],
|
|
retry_on_invalid=current_config["retry_on_invalid"],
|
|
retries=current_config["retries"],
|
|
baudrate=current_config["baudrate"],
|
|
stopbits=current_config["stopbits"],
|
|
bytesize=current_config["bytesize"],
|
|
parity=current_config["parity"],
|
|
strict=current_config["strict"])
|
|
else:
|
|
raise Exception("Invalid Modbus transport type.")
|
|
|
|
available_functions = {
|
|
1: master.read_coils,
|
|
2: master.read_discrete_inputs,
|
|
3: master.read_holding_registers,
|
|
4: master.read_input_registers,
|
|
5: master.write_coil,
|
|
6: master.write_register,
|
|
15: master.write_coils,
|
|
16: master.write_registers,
|
|
}
|
|
return master, available_functions
|
|
|
|
def __stop_connections_to_masters(self):
|
|
for slave in self.__slaves:
|
|
if slave.config.get('master') is not None and slave.config.get('master').is_socket_open():
|
|
slave.config['master'].close()
|
|
|
|
def __function_to_device(self, device, config):
|
|
function_code = config.get('functionCode')
|
|
result = None
|
|
if function_code == 1:
|
|
# why count * 8 ? in my Modbus device one coils is 1bit, tow coils is 2bit,if * 8 can not read right coils
|
|
# result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
|
# count=config.get(OBJECTS_COUNT_PARAMETER,
|
|
# config.get("registersCount",
|
|
# config.get(
|
|
# "registerCount",
|
|
# 1))) * 8,
|
|
# slave=device.config['unitId'])
|
|
|
|
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
|
count=config.get(OBJECTS_COUNT_PARAMETER,
|
|
config.get("registersCount",
|
|
config.get(
|
|
"registerCount",
|
|
1))),
|
|
slave=device.config['unitId'])
|
|
elif function_code in (2, 3, 4):
|
|
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
|
count=config.get(OBJECTS_COUNT_PARAMETER,
|
|
config.get("registersCount",
|
|
config.get(
|
|
"registerCount",
|
|
1))),
|
|
slave=device.config['unitId'])
|
|
elif function_code == 5:
|
|
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
|
value=config[PAYLOAD_PARAMETER],
|
|
slave=device.config['unitId'])
|
|
elif function_code == 6:
|
|
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
|
value=config[PAYLOAD_PARAMETER],
|
|
slave=device.config['unitId'])
|
|
elif function_code in (15, 16):
|
|
result = device.config['available_functions'][function_code](address=config[ADDRESS_PARAMETER],
|
|
values=config[PAYLOAD_PARAMETER],
|
|
slave=device.config['unitId'])
|
|
else:
|
|
self.__log.error("Unknown Modbus function with code: %s", function_code)
|
|
|
|
self.__log.debug("With result %s", str(result))
|
|
|
|
if "Exception" in str(result):
|
|
self.__log.exception(result)
|
|
|
|
return result
|
|
|
|
def on_attributes_update(self, content):
|
|
try:
|
|
device = tuple(filter(lambda slave: slave.name == content[DEVICE_SECTION_PARAMETER], self.__slaves))[0]
|
|
|
|
for attribute_updates_command_config in device.config['attributeUpdates']:
|
|
for attribute_updated in content[DATA_PARAMETER]:
|
|
if attribute_updates_command_config[TAG_PARAMETER] == attribute_updated:
|
|
to_process = {
|
|
DEVICE_SECTION_PARAMETER: content[DEVICE_SECTION_PARAMETER],
|
|
DATA_PARAMETER: {
|
|
RPC_METHOD_PARAMETER: attribute_updated,
|
|
RPC_PARAMS_PARAMETER: content[DATA_PARAMETER][attribute_updated]
|
|
}
|
|
}
|
|
attribute_updates_command_config['byteOrder'] = device.byte_order or 'LITTLE'
|
|
attribute_updates_command_config['wordOrder'] = device.word_order or 'LITTLE'
|
|
self.__process_request(to_process, attribute_updates_command_config,
|
|
request_type='attributeUpdates')
|
|
except Exception as e:
|
|
self.__log.exception(e)
|
|
|
|
def server_side_rpc_handler(self, server_rpc_request):
|
|
try:
|
|
if server_rpc_request.get('data') is None:
|
|
server_rpc_request['data'] = {'params': server_rpc_request['params'],
|
|
'method': server_rpc_request['method']}
|
|
|
|
rpc_method = server_rpc_request['data']['method']
|
|
|
|
# check if RPC type is connector RPC (can be only 'set')
|
|
try:
|
|
(connector_type, rpc_method_name) = rpc_method.split('_')
|
|
if connector_type == self._connector_type:
|
|
rpc_method = rpc_method_name
|
|
server_rpc_request['device'] = server_rpc_request['params'].split(' ')[0].split('=')[-1]
|
|
except (IndexError, ValueError):
|
|
pass
|
|
|
|
if server_rpc_request.get(DEVICE_SECTION_PARAMETER) is not None:
|
|
self.__log.debug("Modbus connector received rpc request for %s with server_rpc_request: %s",
|
|
server_rpc_request[DEVICE_SECTION_PARAMETER],
|
|
server_rpc_request)
|
|
device = tuple(
|
|
filter(
|
|
lambda slave: slave.name == server_rpc_request[DEVICE_SECTION_PARAMETER], self.__slaves
|
|
)
|
|
)[0]
|
|
|
|
# check if RPC method is reserved get/set
|
|
if rpc_method == 'get' or rpc_method == 'set':
|
|
params = {}
|
|
for param in server_rpc_request['data']['params'].split(';'):
|
|
try:
|
|
(key, value) = param.split('=')
|
|
except ValueError:
|
|
continue
|
|
|
|
if key and value:
|
|
params[key] = value if key not in ('functionCode', 'objectsCount', 'address') else int(
|
|
value)
|
|
|
|
self.__process_request(server_rpc_request, params)
|
|
elif isinstance(device.config[RPC_SECTION], dict):
|
|
rpc_command_config = device.config[RPC_SECTION].get(rpc_method)
|
|
|
|
if rpc_command_config is not None:
|
|
self.__process_request(server_rpc_request, rpc_command_config)
|
|
|
|
elif isinstance(device.config[RPC_SECTION], list):
|
|
for rpc_command_config in device.config[RPC_SECTION]:
|
|
if rpc_command_config[TAG_PARAMETER] == rpc_method:
|
|
self.__process_request(server_rpc_request, rpc_command_config)
|
|
break
|
|
else:
|
|
self.__log.error("Received rpc request, but method %s not found in config for %s.",
|
|
rpc_method,
|
|
self.get_name())
|
|
self.__gateway.send_rpc_reply(server_rpc_request[DEVICE_SECTION_PARAMETER],
|
|
server_rpc_request[DATA_PARAMETER][RPC_ID_PARAMETER],
|
|
{rpc_method: "METHOD NOT FOUND!"})
|
|
else:
|
|
self.__log.debug("Received RPC to connector: %r", server_rpc_request)
|
|
except Exception as e:
|
|
self.__log.exception(e)
|
|
|
|
def __process_request(self, content, rpc_command_config, request_type='RPC'):
|
|
self.__log.debug('Processing %s request', request_type)
|
|
if rpc_command_config is not None:
|
|
device = tuple(filter(lambda slave: slave.name == content[DEVICE_SECTION_PARAMETER], self.__slaves))[0]
|
|
rpc_command_config[UNIT_ID_PARAMETER] = device.config['unitId']
|
|
rpc_command_config[BYTE_ORDER_PARAMETER] = device.config.get("byteOrder", "LITTLE")
|
|
rpc_command_config[WORD_ORDER_PARAMETER] = device.config.get("wordOrder", "LITTLE")
|
|
self.__connect_to_current_master(device)
|
|
|
|
if rpc_command_config.get(FUNCTION_CODE_PARAMETER) in (5, 6):
|
|
converted_data = device.config[DOWNLINK_PREFIX + CONVERTER_PARAMETER].convert(rpc_command_config,
|
|
content)
|
|
try:
|
|
rpc_command_config[PAYLOAD_PARAMETER] = converted_data[0]
|
|
except IndexError and TypeError:
|
|
rpc_command_config[PAYLOAD_PARAMETER] = converted_data
|
|
elif rpc_command_config.get(FUNCTION_CODE_PARAMETER) in (15, 16):
|
|
converted_data = device.config[DOWNLINK_PREFIX + CONVERTER_PARAMETER].convert(rpc_command_config,
|
|
content)
|
|
converted_data.reverse()
|
|
rpc_command_config[PAYLOAD_PARAMETER] = converted_data
|
|
|
|
try:
|
|
response = self.__function_to_device(device, rpc_command_config)
|
|
except Exception as e:
|
|
self.__log.exception(e)
|
|
response = e
|
|
|
|
if isinstance(response, (ReadRegistersResponseBase, ReadBitsResponseBase)):
|
|
to_converter = {
|
|
RPC_SECTION: {content[DATA_PARAMETER][RPC_METHOD_PARAMETER]: {"data_sent": rpc_command_config,
|
|
"input_data": response}}}
|
|
response = device.config[
|
|
UPLINK_PREFIX + CONVERTER_PARAMETER].convert(
|
|
config={**device.config,
|
|
BYTE_ORDER_PARAMETER: device.byte_order,
|
|
WORD_ORDER_PARAMETER: device.word_order
|
|
},
|
|
data=to_converter)
|
|
self.__log.debug("Received %s method: %s, result: %r", request_type,
|
|
content[DATA_PARAMETER][RPC_METHOD_PARAMETER],
|
|
response)
|
|
elif isinstance(response, (WriteMultipleRegistersResponse,
|
|
WriteMultipleCoilsResponse,
|
|
WriteSingleCoilResponse,
|
|
WriteSingleRegisterResponse)):
|
|
self.__log.debug("Write %r", str(response))
|
|
response = {"success": True}
|
|
|
|
if content.get(RPC_ID_PARAMETER) or (
|
|
content.get(DATA_PARAMETER) is not None and content[DATA_PARAMETER].get(
|
|
RPC_ID_PARAMETER)) is not None:
|
|
if isinstance(response, Exception):
|
|
self.__gateway.send_rpc_reply(device=content[DEVICE_SECTION_PARAMETER],
|
|
req_id=content[DATA_PARAMETER].get(RPC_ID_PARAMETER),
|
|
content={
|
|
content[DATA_PARAMETER][RPC_METHOD_PARAMETER]: str(response)})
|
|
else:
|
|
self.__gateway.send_rpc_reply(device=content[DEVICE_SECTION_PARAMETER],
|
|
req_id=content[DATA_PARAMETER].get(RPC_ID_PARAMETER),
|
|
content=response)
|
|
|
|
self.__log.debug("%r", response)
|
|
|
|
def get_config(self):
|
|
return self.__config
|
|
|
|
def update_converter_config(self, converter_name, config):
|
|
self.__log.debug('Received remote converter configuration update for %s with configuration %s', converter_name,
|
|
config)
|
|
for slave in self.__slaves:
|
|
try:
|
|
if slave.config[UPLINK_PREFIX + CONVERTER_PARAMETER].__class__.__name__ == converter_name:
|
|
slave.config.update(config)
|
|
self.__log.info('Updated converter configuration for: %s with configuration %s',
|
|
converter_name, config)
|
|
|
|
for slave_config in self.__config['master']['slaves']:
|
|
if slave_config['deviceName'] == slave.name:
|
|
slave_config.update(config)
|
|
|
|
self.__gateway.update_connector_config_file(self.name, self.__config)
|
|
except KeyError:
|
|
continue
|
|
|
|
class ConverterWorker(Thread):
|
|
def __init__(self, name, incoming_queue, send_result, logger):
|
|
super().__init__()
|
|
self._log = logger
|
|
self.stopped = False
|
|
self.setName(name)
|
|
self.setDaemon(True)
|
|
self.__msg_queue = incoming_queue
|
|
self.in_progress = False
|
|
self.__send_result = send_result
|
|
|
|
def run(self):
|
|
while not self.stopped:
|
|
if not self.__msg_queue.empty():
|
|
self.in_progress = True
|
|
convert_function, params = self.__msg_queue.get(True, 10)
|
|
converted_data = convert_function(params)
|
|
if converted_data:
|
|
self._log.info(converted_data)
|
|
self.__send_result(converted_data)
|
|
self.in_progress = False
|
|
else:
|
|
sleep(.001)
|