	About mbusd
mbusd is open-source Modbus TCP to Modbus RTU (RS-232/485) gateway.
Features:
- Small footprint - suitable to run on embedded devices and SBCs like Raspberry Pi
- Multi-master - multiple TCP masters can access slave devices in RTU network using same gateway
- Robustness - can retry requests with mismatched response CRC
- Flexible RTU modes - speed/parity/stop-bits/timeouts can be configured for RTU network
- Support for both of automatic and manual (using RTS bit) direction control types for RS-485 transceivers
Supported function codes:
- 01: Read coil status
- 02: Read input status
- 03: Read holding registers
- 04: Read input registers
- 05: Force single coil
- 06: Preset single register
- 07: Read exception status
- 15: Force multiple coils
- 16: Preset multiple registers
Please note all other function codes (including vendor-specific extensions) are supported on a "best-effort" basis and most likely will fail.
Configuring and compilation:
$ git clone https://github.com/3cky/mbusd.git mbusd.git $ cd mbusd.git $ ./configure $ make # make install $ make clean
Compilation using cmake
$ git clone https://github.com/3cky/mbusd.git mbusd.git $ cd mbusd.git $ mkdir -p output.dir && cd output.dir $ cmake ../ $ make
Usage:
   mbusd [-h] [-d] [-t] [-v level] [-L logfile] [-p device] [-s speed] [-m mode] \
   	       	[-P port] [-C maxconn] [-N retries] [-R pause] [-W wait] [-T timeout]
   -h     Usage help.
   -d     Instruct mbusd not to fork itself (non-daemonize).
   -t     Enable RTS RS-485 data direction control (if not disabled while compile).
   -y file
          Enable RS-485 direction data direction control by writing '1' to file
          for transmitter enable and '0' to file for transmitter disable
   -Y file
          Enable RS-485 direction data direction control by writing '0' to file
          for transmitter enable and '1' to file for transmitter disable
   -v level
          Specifies  log  verbosity level (0 for errors only, 1 for warnings
          and 2 for also information messages.) If mbusd was compiled in debug mode,
          valid log levels are up to 9, where log levels above 2 forces
          logging of information about additional internal events.
   -L logfile
          Specifies log file name ('-' for logging to STDOUT only, default is /var/log/mbusd.log).
   -p device
          Specifies serial port device name.
   -s speed
          Specifies serial port speed.
   -m mode
          Specifies serial port mode (like 8N1).
   -P port
          Specifies TCP port number (default 502).
   -C maxconn
          Specifies maximum number of simultaneous TCP connections.
   -N retries
          Specifies maximum number of request retries (0 disables retries).
   -R pause
          Specifies pause between requests in milliseconds.
   -W wait
          Specifies response wait time in milliseconds.
   -T timeout
          Specifies connection timeout value in seconds (0 disables timeout).
Please note running mbusd on default Modbus TCP port (502) requires root privileges!
Reporting bugs:
Please file issue with attached debug log in verbose (-v9) mode, i.e.:
   # mbusd -L/tmp/mbusd.log -p /dev/ttyUSB0 -s 9600 -P 502 -d -v9
Unless you were prompted so or there is another pertinent reason (e.g. GitHub fails to accept the bug report), please do not send bug reports via personal email.
Contributing:
- Fork it and clone forked repository
- Create your feature branch (git checkout -b my-new-feature)
- Make your changes
- Commit your changes (git commit -am 'Add some feature')
- Push to the branch (git push origin my-new-feature)
- Create new Pull Request
Author:
Victor Antonovich (v.antonovich@gmail.com)
Credits:
Andrew Denysenko (nitr0@seti.kr.ua):
- RTS RS-485 data direction control
- RTU response receiving by length
James Jarvis (jj@aprsworld.com):
- file based RS-485 data direction control
License:
This project is distributed under the BSD license. See the LICENSE file for the full license text.